City of Elk River Design Standards <br />A. Plu.rhing: <br />After the applicable retention period, heavily chlorinated water shall not remain in <br />prolonged contact with the pipe. Chlorinated water shall be flushed from the main until <br />chlorine concentration is no higher than generally� in the sy stem for domestic use. <br />The environment to which the chlorinated water is to be discharged shall be inspected. <br />The Contractor shall be responsible to ensure that the receiving area is not damaged by <br />the chlorinated water and shall use a reducing agent for neutralization when necessary. <br />B. Bacteriological Te.rt.r: <br />After final flushing and before the watermain is placed in service, samples of water shall <br />be collected from the end of the main and each branch line for testing for bacteriological <br />qualit�� in accordance with Standard Methods for the Exainination of Water and <br />Wastewater, and shall show the absence of coliform organisms. Samples shall be at a rate <br />of one per every 1000 feet of pipe. Two consecutive sets of acceptable samples, taken at <br />least 24 hours apart, must be collected from each sample point on the new main. The <br />first sample must be taken a minimum of 24 hours after flushing. A higher rate of <br />sampling may be required to include all branch line. If water in the pipe does not meet <br />the Minnesota Department of Health requirements, disinfection procedure shall be <br />repeated until meeting the requirements. The pulling of all samples shall be witnessed by <br />a representative of Elk River Municipal Utilities. <br />3. Electrical Conductivin� Tests <br />A conductivity test within one week after comple�ion of pressure testing of the watermain on all <br />ductile iron pipe watermain will be required. <br />On watermain reconstruction projects, the Contractor shall perform the conductivity test prior <br />to ser�rice line reconnections to ensure main line isolation from house ser�rices. <br />The system (pipeline, �ralves, fittings and hydrants) shall be tested for electrical continuin� and <br />current capaciry. The electrical test shall be made after the hydrostatic pressure test and while <br />the line is at normal operating pressure. Backfilling shall ha�re been completed. The line may� be <br />tested in sections of convenient length as approved by ER1�ZU. <br />Direct current of 350 amperes plus or minus 10%, shall be passed through the pipeline for 5 <br />minutes. Current flow through the pipe shall be measured continuously� on a suitable ammeter <br />and shall remain steady without interruption or fluctua�ion throughout the 5-minute test period. <br />Insufficient current or intermittent current or arcing, indicated by large fluctuation of the <br />ammeter needle, shall be evidence of defective contact in the pipeline. The cause shall be <br />isolated and corrected. Thereafter, the section in which the defective test occurred shall be <br />retested as a unit and shall meet the requirements. <br />Sources of D.C. for these tests may be motor generators, arc welding machines, or other <br />appro�red sources. All such equipment shall be furnished by� the Contractor. <br />Cables from the power source to the section of system under test should be of sufficient size to <br />carry the test current without o�rerheating or excessive �roltage drop. <br />Electrical conductivity testing shall not be performed on plastic or HDPE watermain. Tracer <br />(location) testing of all watermain shall be completed after all service installations have been <br />completed. <br />OO City of Elk River, Minnesota — All rights reserved I 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.