MORATORIUM EFFECTIVE FEBRUARY 14, 2017 ON THE Ff1 i nWtiril\ir LOAD CONTROL PROGRAMS <br /> Energy Management Program Rates <br /> Electric Thermal Storage (ETS)Space Heating Rate: This Program is available to all ERMU customers. <br /> An ETS space heating system is designed to store heat produced by electricity generated during eight <br /> off-peak hours for use in heating during the remaining on-peak hours daily. Off-peak hours typically <br /> occur between 11 PM and 7 AM. Qualifying ETS configurations may be central storage furnaces, room <br /> storage heaters or slab (deep heat) systems including combinations of same. <br /> To qualify for the special rate,the customer shall provide: <br /> 1. An ETS space heating system listed by UL or some other nationally recognized testing agency <br /> which can be interrupted by a single 5 amp rated relay. <br /> 2. Obtain a load control device from ERMU. <br /> 3. Accommodations for a meter and load control device and associated wiring installed according <br /> to the applicable electrical codes, and installed by a qualified electrician. <br /> 4. Inspection by a State certified electrical inspector and a representative of ERMU. <br /> ERMU shall provide: <br /> 1. All electric energy consumed by this ETS system at$0.0486046-3 per kWh. <br /> 2. This equipment will be energized only for 8 off peak hours daily. Additional on-time is provided <br /> on weekend days and holidays. <br /> 3. A meter to measure electricity consumed by the ETS space heating system. <br /> 4. A load control device which will automatically control ETS space heating system during on-peak <br /> hours. <br /> Rate is subject to application of Power Cost Adjustment (PCA). <br /> Federal, state, and local taxes may apply. <br /> Electric Thermal Storage(ETS)Water Heating Rate:This Program is available to all ERMU customers. <br /> An ETS water heater is designed with extra storage capacity to provide total domestic hot water needs <br /> from electricity consumed only during eight off-peak hours daily. Off-peak hours typically occur between <br /> 11 PM and 7 AM. Qualifying ETS configurations may be a large single tank, dual tanks plumbed in series, <br /> or an electric and non-electric tank plumbed in series with the electric placed on the cold water side. <br /> Electric water heater must have an energy factor of.91 or more and a minimum of 80 gallons of storage <br /> capacity. <br /> To qualify for the special rate,the customer shall provide: <br /> 1. An ETS water heating system which can be interrupted directly by a single 30 amp rated relay. <br /> 2. Obtain a load control device from ERMU. <br /> 3. Accommodations for a meter and load control device and associated wiring installed according <br /> to the applicable electrical codes, and installed by a qualified electrician. <br /> 4. Inspection by a State certified electrical inspector and a representative of ERMU. <br /> 5. This rate is not available for hot water use in any production process for Commercial and <br /> Industrial users. <br /> Page 2 of 3 <br /> 119 <br />