2. Light and Ventilation <br />a. HVAC system does not meet mechanical /building code. <br />3. Fire Protection /Adequate Egress <br />a. Current wood handicap ramp lacks code - compliant protective handrails. <br />b. Replace entrance door hardware with code - compliant egress style. <br />c. Rear entrance concrete steps are not level with door threshold as per code. <br />d. There is no code - compliant emergency egress window in basement to provide secondary <br />exit. <br />e. R3 Residential Group classification requires automatic fire sprinkler system building -wide. <br />4. Layout and Condition of Interior Partitions /Materials <br />a. Interior walls and ceilings should be repaired /repainted. <br />b. Exposed copper piping should be attached to walls. <br />c. Kitchen casework should be painted. <br />d. Baseboard should be replaced where missing. <br />e. Door trim should be installed. <br />f. Water stained floor should be re -sanded and finished. <br />g. Miscellaneous debris should be removed from basement. <br />h. Ceiling tile should be replaced in basement. <br />i. Basement fire place brick should be cleaned. <br />5. Exterior Construction <br />a. Wood soffits and eaves on rear of house need to be painted /covered to prevent water <br />intrusion. <br />b. Wood windows need to be painted and caulked to prevent water intrusion. <br />c. Wood siding on rear of house is peeling and needs to be painted to prevent water intrusion. <br />Description of Code Deficiencies <br />I. Current wood handicap ramp lacks code - compliant protective handrails. <br />2. Replace entrance door hardware with code - compliant style. <br />3. Replace non - compliant rear entrance concrete steps level with threshold per code. <br />4. Wood soffits and eaves on rear of house need to be painted /covered to prevent water intrusion. <br />5. Wood windows need to be painted and caulked to prevent water intrusion. <br />6. Wood siding on rear of house needs to be painted to prevent water intrusion. <br />7. Replace non - compliant forced air heating system and controls to meet code. <br />8. Modify non - compliant basement bathroom per code. <br />9. Replace non - complaint ceiling mounted gas heater located in attached garage to meet code. <br />10. Provide AFCI protected receptacles per code. <br />11. Provide GFCI protected receptacles in Kitchen. <br />12. Repair non - compliant basement wall outlets that are loose and have unprotected wiring. <br />13. Repair electrical outlets adjacent to main electrical panel that are damaged and are not code <br />compliant. <br />14. Install code - required automatic fire sprinkler system. <br />15. Install code - required basement emergency egress window. <br />Beaudry Redevelopment TIF District #24 Page 2 of 3 Building Report <br />LHB Project No. 170323 Parcel F, Residence <br />