Laserfiche WebLink
e. A code required stair railing should be installed. <br /> f. Second floor bathroom should be repaired/repainted. <br /> g. The basement floor to ceiling height is not code compliant. <br /> 5. Exterior Construction <br /> a. Roof has failed and is allowing for water intrusion contrary to code. There is evidence of <br /> water intrusion on the second-floor ceiling. <br /> b. Windows are damaged and allowing for water intrusion contrary to code. <br /> c. Exterior wood siding is damaged and allowing for water intrusion contrary to code. <br /> d. Gutters need to be painted. <br /> e. Soffit and fascia have holes from woodpeckers which is allowing for water intrusion, <br /> contrary to code. <br /> f. Chimney is damaged and missing mortar,allowing for water intrusion and contrary to code. <br /> Description of Code Deficiencies <br /> 1. HVAC system is not mechanical/building code compliant. <br /> 2. Code compliant smoke detectors should be installed. <br /> 3. Code required carbon monoxide detectors should be installed. <br /> 4. Code required fire extinguisher should be installed. <br /> 5. Code required AFCI's should be installed. <br /> 6. Code compliant,grounded electrical outlets should be installed. <br /> 7. Stairway to second floor should be made code compliant for rise and run of stair treads. <br /> 8. Stairway to second floor should have a code required handrail installed. <br /> 9. Basement floor to ceiling height should be corrected to comply with code. <br /> 10. Replace roof to prevent water intrusion per code. <br /> 11. Replace windows to prevent water intrusion per code. <br /> 12. Repair wood siding to prevent water intrusion per code. <br /> 13. Repair soffit and facia to prevent water intrusion per code. <br /> 14. Repair foundation cracks to prevent water intrusion per code. <br /> 15. Repair chimney to prevent water intrusion per code. <br /> Overview of Deficiencies <br /> This one and a half story residential dwelling is currently being rented. The interior and exterior surfaces <br /> should be repaired and repainted. The flooring should be replaced. There are no code compliant smoke <br /> detectors,carbon monoxide detectors or fire extinguishers installed. Access to the second-floor lacks code <br /> compliant rise and run of the stair treads. There is no code required hand railing on the second-floor <br /> stairway. There are no code required AFCI's. The electrical outlets do not have code required grounding. <br /> The roof and windows should be replaced to become code compliant. The wood siding,soffit and fascia <br /> should be repaired to prevent water intrusion per code. The foundation and chimney should be repaired to <br /> prevent water intrusion per code. <br /> 0:\17Pioj\170323\400 Design\406 Reports\Building Reports\170323 623 Pfoctor Ave Building Reportdocx <br /> Beaudry Redevelopment TIF District#24 Page 2 of 2 Building Report <br /> LHB Project No. 170323 Parcel I, Residence <br />