Laserfiche WebLink
g. Wood floors need to be refinished. <br /> h. The bathroom toilet is not code compliant for distance from door. <br /> i. The bathroom exhaust system is not code compliant. <br /> j. The stairs to the second floor do not comply with code. <br /> k. The floor to ceiling height on the second floor does not comply with code. <br /> 5. Exterior Construction <br /> a. Front entrance steps are not code compliant for tread rise. <br /> b. Exterior wood surfaces need painting. <br /> c. Foundation block mortar is separating or missing and needs to be replaced to prevent water <br /> intrusion per code. <br /> d. The windows are allowing for water intrusion contrary to code. <br /> Description of Code Deficiencies <br /> 1. The HVAC system does not comply with code. <br /> 2. Code compliant smoke detectors should be installed. <br /> 3. Code required carbon monoxide detectors should be installed. <br /> 4. Install code required grounded electrical outlets. <br /> 5. Install code required AFCI's. <br /> 6. The basement stairs should be modified to comply with code. <br /> 7. The stairway to the second floor should be modified to comply with code. <br /> 8. The electrical circuit box does not comply with code. <br /> 9. The side door entering the basement stairway landing does not comply with code. <br /> 10. The bathroom toilet does not comply with code for distance from door. <br /> 11. The bathroom toilet exhaust is not code compliant. <br /> 12. The second-floor stairway is not code compliant. <br /> 13. The floor to ceiling height on the second floor does not comply with code. <br /> 14. The front entrance steps are not code compliant. <br /> 15. Mortar on the foundation block needs to be repaired to prevent water intrusion per code. <br /> 16. Windows should be replaced to prevent water intrusion per code. <br /> Overview of Deficiencies <br /> This residential dwelling needs a new HVAC system to comply with code. There are no code compliant <br /> smoke detectors in the residence. There are no code required carbon monoxide detectors in the home. <br /> Electrical outlets are not grounded and do not comply with code. Both the basement and the second floor <br /> stairways do not comply with code. The interior walls and ceilings need repair/repainting. The floor to <br /> ceiling height does not comply with code on the second floor. Windows should be replaced to prevent water <br /> intrusion. <br /> 0:\17Pioj\170323\400 Design\406 Reports\Building Reports\170323 1234 6th St Building Reportdocx <br /> Beaudry Redevelopment TIF District#24 Page 2 of 2 Building Report <br /> LHB Project No. 170323 Parcel D, Residence <br />