Laserfiche WebLink
e. Flooring needs to be replaced. <br /> f. Ceiling exhibits water staining and should be repainted. <br /> g. Floor to ceiling height does not meet code in second floor bathroom. <br /> h. Interior window trim is water stained. <br /> i. Basement floor to ceiling height does not comply with code. <br /> j. Install code required emergency egress windows in basement. <br /> 5. Exterior Construction <br /> a. Exterior window trim needs repair. <br /> b. Front step carpeting needs to be replaced. <br /> c. Windows are broken and should be repaired per city code. <br /> Description of Code Deficiencies <br /> 1. HVAC system is not mechanical/building code compliant. <br /> 2. Code compliant smoke detectors should be installed. <br /> 3. Code compliant carbon monoxide detectors should be installed. <br /> 4. Code required AFCI's should be installed. <br /> 5. Code required building sprinkler system should be installed. <br /> 6. Code required emergency notification system should be installed. <br /> 7. Stair tread needs to be modified on second floor to comply with code. <br /> 8. Bathroom on second floor needs to be modified to comply with code for distance in front of toilet. <br /> 9. Floor to ceiling height on second floor bathroom needs to be modified to comply with code, <br /> 10. Basement floor to ceiling height needs to be modified to comply with code. <br /> 11. Foundation walls need to be rebuilt to hold back earthen material per code. <br /> 12. Install emergency egress windows in basement to comply with code. <br /> 13. Repair broken windows per code. <br /> Overview of Deficiencies <br /> This building has six rental units. Each of the units will require new flooring and painting. There are no code <br /> required carbon monoxide detectors in any of the units. There is no code required building wide sprinkler <br /> system. The basement floor to ceiling height does not meet code. The second floor bathroom floor to <br /> ceiling height does not meet code. There are no code required AFCI's in the building. There are no <br /> compliant smoke detectors in the building. Stair treads on the second floor need to be modified to comply <br /> with code for rise. The foundation is compromised and should be rebuilt per code. <br /> 0:\17Proj\170323\400 Design\406 Reports\Building Reports\170323 706 Quinn Ave Building Report.docx <br /> Beaudry Redevelopment TIF District#24 Page 2 of 2 Building Report <br /> LHB Project No. 170323 Parcel A, Rental Units <br />