This site is not expected to cause a recognized environmental condition on the Property. <br /> B6. Cinema Professional Building, 657 Main Street, Elk River; located approximately 3/16 <br /> mile east-southeast of the Property in a published sidegradient groundwater flow direction <br /> from the Property. <br /> Liesch conducted a Remedial Investigation at this site in 1990. The report, dated <br /> October 1990, stated that a UST was discovered in the garage. According to the report, <br /> soil borings were installed and water levels were measured. The cross sectional diagrams <br /> of the borings suggest that groundwater flow is to the southeast towards the Mississippi <br /> River. The report recommended, "the state fire marshall be contacted and approval <br /> obtained to close the tank in place" due to its location. <br /> Liesch contacted Mr. Brad Norberg, the MPCA project hydrogeologist assigned to this <br /> leak site (#3388). Mr. Norberg stated that this site has not been granted closure at this <br /> time. A letter was sent to the responsible party from the MPCA in March 1993 <br /> requesting information to assure that the underground storage tank at the site was <br /> abandoned according to MPCA guidelines. <br /> Due to groundwater flow direction at this site, based on the Remedial Investigation <br /> 10 condition dated October 1990, this site is not expected to cause a recognized environmental <br /> condition on the Property. <br /> Unmappable Sites <br /> EDR was unable to map a number of sites due to inadequate address information. These sites <br /> are listed on page 16 of Appendix B where they are noted as an "Orphan Summary". Liesch <br /> located these sites and determined that two are within the search radius of the various categories <br /> of the Property. Liesch has plotted the approximate locations of those sites within the study area <br /> on the maps in Appendix B and discusses them below. The discussions are numbered to <br /> correspond with map locations and the sequence number added to page 16 of Appendix B by <br /> Liesch. <br /> Site number 11, North Suburban Orthopedics, is noted on the RCRIS-SQG list and the FINDS <br /> database (search radius 0.25 mile within the study area). <br /> Inclusion on these lists does not imply the facility has environmental problems or that a release <br /> has occurred. <br /> B.A.LIESCH ASSOCIATES,INC. <br /> May 1996 Hydrogeologists•Engineers•Environmental Scientists •page 5• <br />