Laserfiche WebLink
Bidder <br />Triple Combination Pumper Specifications for the 62 Complies <br />Cit of Elk River Minnesota Yes No <br /> I <br />Direct drive (PTO) and portable generator installations shall comply with Article 445 <br />(Generators) of thc NEC. <br />Overcurrent protection <br />The conductors used in the power supply assembly between the output terminals of the power <br />source and the main over current protection device shall not exceed 144 inches. (3658 mm) in <br />length. <br />For fixed power supplies, all conductors in the power supply assembly shall be type THHW, <br />THW, or use stranded conductors enclosed in nonmetallic liquid tight flexible conduit rated for <br />a minimum of 194 degrees Fahrenheit (90 degrees Celsius). <br />For portable power supplies, conductors located between the power source and the line side of <br />the main overcurrent protection device shall be type SO or type SEO with suffix WA flexible <br />cord rated for 600-volts at 194 degrees Fahrenheit (90 degrees Celsius). <br />Wiring Methods <br />Fixed wiring systems shall be limited to the following: <br />- Metallic or nonmetallic liquid tight flexible conduit rated at not less than 194 degrees <br />Fahrenheit (90 degrees Celsius) <br />or <br />- Type SO or Type SEO cord with a WA suffix, rated at 600 volts at not less than 194 <br />degrees Fahrenheit (90 degree Celsius) <br />Electrical cord or conduit shall not be attached to chassis suspension components, water or <br />fuel lines, air or air brake lines, fire pump piping, hydraulic lines, exhaust system components, <br />or low voltage wiring. In addition the wiring shall be run as follows: <br />- Separated by a minimum of 12 inches (305 mm), or properly shielded, from exhaust <br />piping , <br />- Separated from fuel lines by a minimum of six (6) inches (152 mm) distance. <br />Electrical cord or conduit shall be supported within six (6) inches (152 mm) of any junction <br />box and at a minimum of every 24 inches (610 mm) of continuous run. Supports shall be made <br />of nonmetallic materials or corrosion protected metal. All supports shall be of a design that <br />does not cut or abrade the conduit or cable and shall be mechanically fastened to the vehicle. <br />Wiring Identification <br />All line voltage conductors located in the main panel board shall be individually and <br />permanently identified. The identification shall reference the wiring schematic or indicate the <br />final termination point. When prewiring for future power sources or devices, the unterminated <br />Page 62 <br /> <br /> <br />