My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5.4.& 5.6. PCSR 01-09-2007
ElkRiver
>
City Government
>
Boards and Commissions
>
Planning Commission
>
Planning Packets
>
2006-2010
>
2007
>
01-09-2007
>
5.4.& 5.6. PCSR 01-09-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2008 4:05:02 PM
Creation date
2/13/2007 11:43:08 AM
Metadata
Fields
Template:
City Government
type
PCSR
date
1/9/2007
case
CU 07-04
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. <br /> <br />. <br /> <br />. <br /> <br /> <br />MEMORANDUM <br /> <br />TO: Jeremy Barnhart, Planning Manager <br /> <br />Terry Maurer, City Engineer .~ <br />DATE: january 2, 2007 <br /> <br />FROM: <br /> <br />SUBJECT: UnitedHealth Group Technology Center <br />File #226-1 54P <br /> <br />As requested, we have reviewed the submittal package for the UnitedHealth Group. <br />Technology Center. The package consisted of a plan set prepared by RLK, Inc. dated <br />November 22, 2006 and a preliminary drainage report, again prepared by RLK, Inc. with the <br />same date. Based upon our review, we would offer the following comments: <br /> <br />1. The drainage calculations have been reviewed and are approved. The drainage concept <br />consists of three ponding areas on the site, once each at the southeast and southwest <br />comers of the building which take flow from the south side of the building. Each of <br />these then overflows into a larger pond located along Business Center Drive. The <br />ponding system is set up to contain two back-to-back l00-year storms without <br />discharging. There are emergency overflows connected to the storm sewer within <br />Business Center Drive, should a larger event occur. <br /> <br />2. The water system has been reviewed and is approvable. In consists of an 8-inch <br />diameter loop around the entire perimeter of the building, connecting at two locations to <br />the existing la-inch watermain located along the south side of the site. Drainage and <br />utility easements will be needed for the entire watermain loop around the building. This <br />watermain loop will be considered a public facility since it contains fire hydrants, which <br />must be maintained and operated by the Elk River Municipal Utilities. The Fire Chief <br />has reviewed the hydrant locations and has approved the proposed six hydrant locations <br />around the building perimeter. It should be noted that the new hydrant located on the <br />south side center of the building is shown with a hydrant symbol, but the construction <br />note does not indicate the hydrant. <br /> <br />There is a proposed hydrant symbol shown near the driveway on Waco Street. There is <br />no note associated with this hydrant. It is unclear whether or not the existing hydrant in <br />
The URL can be used to link to this page
Your browser does not support the video tag.