WH
<br />01 EXISTING OVERHEAD GARAGE DOOR, 10'
<br />X 10'
<br />04 EXISTING HEATED CONC. FLOORING, NO
<br />WORK IS DONE TO MODIFY FLOORLING
<br />02EXISTING GARAGE DOOR, SEE
<br />SCHEDULE 02 EXISTING GARAGE DOOR, SEE
<br />SCHEDULE
<br />5' - 0"
<br />49' - 3"21' - 2 3/4"
<br />03 EXISTING WINDOW
<br />02 EXISTING GARAGE DOOR, SEE
<br />SCHEDULE
<br />03EXISTING WINDOW
<br />32' - 0"12' - 6"8' - 4"5' - 1 7/8"01 EXISTING OVERHEAD GARAGE DOOR, 10'
<br />X 10'5' - 0"10' - 0"2' - 0"10' - 0"5' - 0"WAREHOUSE
<br />STORAGE
<br />001
<br />PACKAGING AREA
<br />002
<br />1' - 2"4' - 10"1' - 2"4' - 10"1' - 2"4' - 10"1' - 2"4' - 10"1' - 2"4' - 10"2' - 0"03EXISTING WINDOW
<br />03EXISTING WINDOW
<br />03EXISTING WINDOW
<br />03EXISTING WINDOW
<br />03EXISTING WINDOW03EXISTING WINDOW
<br />2' - 10"4' - 10"4' - 10"3' - 0"
<br />21' - 2 3/4"
<br />03 EXISTING WINDOW
<br />4 3/4" ASSUMED 49' - 3"4 3/4" ASSUMED 4 3/4" ASSUMED6' - 11"2' - 1"2' - 9"
<br />06LINE OF EXISTING FRP-1, 8' TALL
<br />05 EXISTING FLOOR DRAIN
<br />07 FF&E SHOWN FOR GRAPHIC CLEARITY
<br />ONLY, SEE FF&E SHEET
<br />08 EXISTING EXTERIOR TO REMAIN AS-IS,
<br />NO WORK TO MODIFY STRUCTURE
<br />09 EXISTING INTERIOR WALLS TO REMAIN
<br />AS-IS, NO WORK TO MODIFY STRUCTURE
<br />10 EXISTING INTERIOR WALLS TO REMAIN
<br />AS-IS, NO WORK TO MODIFY INTERIOR
<br />10EXISTING INTERIOR WALLS TO REMAIN
<br />AS-IS, NO WORK TO MODIFY INTERIOR
<br />3' - 0"1' - 3 5/8"1' - 3 5/8"
<br />001A
<br />001B
<br />001C
<br />002B
<br />002A
<br />002C
<br />EXISTING & DEMO LINE TYPE
<br />DEMO
<br />EXISTING WALL
<br />EXISTING AREA
<br />NEW WALL
<br />GENERAL BUILDING PLAN NOTES:
<br />1. SCALE & ORIENTATION: ALL DIMENSIONS ARE INDICATED ON THE
<br />DRAWING. NORTH ARROW INDICATING THE ORIENTATION OF THE
<br />PLAN. DIMENSIONS AT INTERIOR PARTITIONS ARE TO FACE OF
<br />SHEATHING OF FRAMING UNLESS NOTED OTHERWISE. WHERE CLEAR
<br />DIMENSIONS ARE NOTED, THESE MUST BE MAINTAINED. NOTIFY THE
<br />ARCHITECT AND OWNER IF DIMENSION ARE NOT CLEAR.
<br />2. MATERIALS: ALL MATERIALS SHALL COMPLY WITH RELEVANT
<br />BUILDING CODES AND REGULATIONS.
<br />3. CODE COMPLIANCE: THIS DRAWING IS BASED ON THE LATEST
<br />APPLICABLE BUILDING CODES AND REGULATIONS. ANY UPDATES OR
<br />CHANGES TO CODES DURING CONSTRUCTION SHALL BE ADHERED
<br />TO. THE ARCHITECT IS NOT RESPONSIBLE FOR ANY CHANGES OR
<br />DEVIATIONS MADE TO THE PLANS WITHOUT PRIOR CONSULTATION
<br />AND APPROVAL.
<br />4. ACCESSIBILITY: DESIGN COMPLIES WITH ADA (AMERICANS WITH
<br />DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
<br />ACCESSIBLE ROUTES, RAMPS, AND OTHER NECESSARY FACILITIES
<br />ARE SHOWN ON THE PLAN
<br />5. COORDINATION: GENERAL CONTRACTOR TO COORDINATE THIS
<br />PLAN WITH MECHANICAL. ELECTRICAL AND PLUMBING
<br />SUBCONTRACTORS AS TO LOCATIONS FOR EQUIPMENT, FIXTURES,
<br />METERS, DUCTWORK ETC TO BE UP TO CODE. NOTIFY ARCHITECT
<br />IMMEDIATELY OF ANY CONFLICTS BETWEEN ARCHITECTURAL
<br />DRAWINGS AND MEP SUBCONTRACTORS.
<br />5A. ALL OPENINGS CUT, OPENINGS MADE OR EQUIPMENT INSTALLED
<br />IN FIRE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE
<br />RESTORED SEALED FIRESTOPPED OR OTHERWISE CONSTRUCTED
<br />TO MAINTAIN THE INTEGRITY OF THE FIRE RATING TO THE FULL
<br />SATISFACTION OF THE ARCHITECT, ENGINEER AND BUILDING
<br />OFFICIAL. THE GENERAL CONTRACTOR SHALL COORDINATE AND BE
<br />RESPONSIBLE FOR THIS WORK.
<br />5B. SEAL TOP SIDE OF PRECAST PLANK AND UNDERSIDE OF
<br />PRECAST PLANK AT ALL VERTICAL PENETRATIONS.
<br />5C. ALL EXPOSED PIPES, VENTS AND CONDUIT PENETRATING
<br />WALLS, FLOORS OR CEILINGS SHALL HAVE FINISHED TRIM RINGS
<br />(ESCUCHEONS).
<br />5D. WHERE ACCESS PANELS ARE REQUIRED FOR EQUIPMENT,
<br />UTILITIES OR DEVICES, THOSE PANELS SHALL BE INSTALLED
<br />WHETHER OR NOT THEY ARE SPECIFICALLY SHOWN ON THE
<br />DRAWINGS. WHEN INSTALLED IN A FIRE RATED ASSEMBLY, ACCESS
<br />PANEL MUST BE FIRE RATED TO MATCH RATING OF THAT ASSEMBLY.
<br />VERIFY ALL LOCATIONS WITH ARCHITECT BEFORE INSTALLING.
<br />5E. PROVIDE BLOCKING IN WALLS FOR MOUNTING EQUIPMENT,
<br />RAILS, STOPS, CASEWORK AND ALL OTHER SPECIALTIES AND
<br />ACCESSORIES.
<br />6. CHANGES AND REVISIONS: ANY CHANGES OR REVISIONS TO THE
<br />PLANS MUST BE APPROVED BY THE ARCHITECT TO ENSURE
<br />COMPLIANCE WITH THE DESIGN INTENT AND RELEVANT
<br />REGULATIONS.
<br />7. OWNER’S RESPONSIBILITIES: THE OWNER IS RESPONSIBLE FOR
<br />OBTAINING ALL NECESSARY PERMITS AND APPROVALS FROM LOCAL
<br />AUTHORITIES. THE OWNER IS RESPONSIBLE FOR PROVIDING
<br />ACCURATE SURVEY DATA AND INFORMATION ABOUT SITE
<br />CONDITIONS.
<br />8. DISCLAIMER: THIS DRAWING IS FOR GENERAL INFORMATION
<br />PURPOSES ONLY. THE ARCHITECT MAKES NO WARRANTIES,
<br />EXPRESSED OR IMPLIED, REGARDING ITS ACCURACY OR
<br />COMPLETENESS.
<br />THE ARCHITECT SHALL NOT BE LIABLE FOR ANY DAMAGES OR
<br />LOSSES RESULTING FROM THE USE OF THIS DRAWING WITHOUT
<br />PROPER CONSULTATION AND COORDINATION.
<br />Attn: This drawing does not include Mechanical, Electrical, or Plumbing
<br />(MEP) details. Refer to separate MEP drawings for those specifications.
<br />GENERAL DEMOLITION PLAN NOTES:
<br />1. SCOPE OF DEMOLITION: THE DEMOLITION PLAN INDICATES THE
<br />EXTENT OF DEMOLITION WORK TO BE PERFORMED.
<br />ONLY AREAS SHOWN AS DEMOLISHED ON THIS PLAN SHALL BE
<br />SUBJECT TO DEMOLITION.
<br />2. SAFETY PRECAUTIONS: PRIOR TO COMMENCING DEMOLITION
<br />WORK, ALL NECESSARY SAFETY MEASURES MUST BE IMPLEMENTED
<br />ACCORDING TO OSHA (OCCUPATIONAL SAFETY AND HEALTH
<br />ADMINISTRATION) REGULATIONS. PROTECTIVE BARRIERS, SIGNAGE,
<br />AND SAFETY EQUIPMENT MUST BE PROVIDED AND MAINTAINED
<br />THROUGHOUT THE DEMOLITION PROCESS.
<br />3. ENVIRONMENTAL CONSIDERATIONS: DEMOLITION ACTIVITIES
<br />SHALL COMPLY WITH ALL ENVIRONMENTAL REGULATIONS AND
<br />GUIDELINES. PROPER DISPOSAL METHODS FOR HAZARDOUS
<br />MATERIALS, INCLUDING ASBESTOS, LEAD, AND OTHER
<br />CONTAMINANTS, MUST BE FOLLOWED.
<br />4. UTILITIES DISCONNECTION: ALL UTILITIES (ELECTRICAL, PLUMBING,
<br />HVAC, ETC.) SHALL BE PROPERLY DISCONNECTED AND TERMINATED
<br />AS PER LOCAL CODES AND UTILITY PROVIDER REQUIREMENTS.
<br />COORDINATION WITH UTILITY COMPANIES IS NECESSARY TO ENSURE
<br />SAFE DISCONNECTION AND REMOVAL OF SERVICES
<br />5. STRUCTURAL STABILITY: STRUCTURAL ELEMENTS TO REMAIN
<br />SHALL BE PROTECTED FROM DAMAGE DURING DEMOLITION
<br />OPERATIONS. ANY TEMPORARY BRACING OR SHORING REQUIRED
<br />TO MAINTAIN STRUCTURAL STABILITY DURING DEMOLITION SHALL
<br />BE PROVIDED AS NECESSARY.
<br />6. WASTE MANAGEMENT: DEMOLISHED MATERIALS SHALL BE
<br />SORTED AND DISPOSED OF IN ACCORDANCE WITH APPLICABLE
<br />WASTE MANAGEMENT REGULATIONS. SALVAGEABLE MATERIALS
<br />SHOULD BE IDENTIFIED AND SALVAGED WHENEVER FEASIBLE TO
<br />MINIMIZE WASTE AND PROMOTE SUSTAINABILITY.
<br />7. SITE PROTECTION: THE SITE SHALL BE PROTECTED FROM
<br />UNAUTHORIZED ACCESS DURING DEMOLITION ACTIVITIES.
<br />FENCING, BARRICADES, AND OTHER MEASURES SHALL BE
<br />INSTALLED TO PREVENT ACCIDENTS AND MAINTAIN SITE SECURITY.
<br />8. COORDINATION WITH AUTHORITIES: DEMOLITION WORK SHALL BE
<br />CONDUCTED IN COORDINATION WITH LOCAL AUTHORITIES,
<br />INCLUDING OBTAINING NECESSARY PERMITS AND APPROVALS.
<br />COMPLIANCE WITH NOISE ORDINANCES, TRAFFIC REGULATIONS,
<br />AND OTHER LOCAL REQUIREMENTS IS MANDATORY.
<br />9. EMERGENCY PROCEDURES: EMERGENCY PROCEDURES,
<br />INCLUDING EVACUATION ROUTES AND CONTACT INFORMATION FOR
<br />EMERGENCY SERVICES, SHALL BE PROMINENTLY DISPLAYED ON-
<br />SITE.
<br />10. OWNER’S RESPONSIBILITIES: THE OWNER IS RESPONSIBLE FOR
<br />SECURING NECESSARY PERMITS AND APPROVALS FOR DEMOLITION
<br />WORK. THE OWNER SHALL PROVIDE ACCESS TO THE SITE AND
<br />COOPERATE WITH THE DEMOLITION CONTRACTOR AS NEEDED.
<br />11. DISCLAIMER: THIS DRAWING IS FOR INFORMATIONAL PURPOSES
<br />ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF THEIR
<br />RESPONSIBILITY TO CONDUCT A THOROUGH SITE ASSESSMENT AND
<br />IMPLEMENT APPROPRIATE DEMOLITION METHODS.
<br />THE ARCHITECT ASSUMES NO LIABILITY FOR DAMAGES OR LOSSES
<br />RESULTING FROM THE USE OF THIS DRAWING WITHOUT PROPER
<br />CONSULTATION AND COORDINATION.
<br />Attn: This drawing does not include Mechanical, Electrical, or Plumbing
<br />(MEP) details. Refer to separate MEP drawings for those specifications.
<br />RevDescriptionDateI hereby certify that this plan, specifications or report was
<br />prepared by me and under my direct supervision, and that
<br />I am a dully Licensed Architect under the laws of the State
<br />Mennesota.
<br />Printed Name:
<br />Signature:
<br />Date: Licensed #:
<br />Scale: As indicated
<br />Project #: 25-0316
<br />A2EL ROJO WHOLESALE
<br />14270 201ST AVE NW, ELK RIVER, MN 55330
<br />Drawn By: CT
<br />Checked By: KW
<br />FLOOR PLAN -
<br />LEVEL 1
<br />KERRIK WESSEL
<br />4593003/25/25
<br />Approved By: BG
<br /> 1/4" = 1'-0"A2
<br />1FLOOR PLAN - EXISTING EXISTING PLAN NOTES
<br />NOTE
<br />NUMBER NOTE DESCRIPTON
<br />01 EXISTING OVERHEAD GARAGE DOOR, 10' X 10'
<br />02 EXISTING GARAGE DOOR, SEE SCHEDULE
<br />03 EXISTING WINDOW
<br />04 EXISTING HEATED CONC. FLOORING, NO WORK IS DONE TO MODIFY FLOORLING
<br />05 EXISTING FLOOR DRAIN
<br />06 LINE OF EXISTING FRP-1, 8' TALL
<br />07 FF&E SHOWN FOR GRAPHIC CLEARITY ONLY, SEE FF&E SHEET
<br />08 EXISTING EXTERIOR TO REMAIN AS-IS, NO WORK TO MODIFY STRUCTURE
<br />09 EXISTING INTERIOR WALLS TO REMAIN AS-IS, NO WORK TO MODIFY STRUCTURE
<br />10 EXISTING INTERIOR WALLS TO REMAIN AS-IS, NO WORK TO MODIFY INTERIOR
<br />REAR ELEVATION
<br />SIDE ELEVATION