4 PP1343 SFS2300 SF/OCC <br />EXIT <br />EXIT46' - 0"29' - 0"BATHROOM <br />WAREHOUSE STORAGE <br />PACKAGING AREA <br />6 PP636 SFF2100 SF/OCC <br />EXIT <br />FE <br />FE <br />28' - 6"16' - 0" <br />HALLWAY <br />PROJECT NARRATIVE: <br />NOTE: BUILDING AREAS INDICATED ARE NOT BOMA RENTABLE AREA CALCULATIONS <br />CODE DATA - 2020 MNBC <br />EL ROJO WHOLESALE PACKAGE DRY GOOD (SNACKS) FROM BULK INTO SMALLER <br />QUANTITIES FOR RETAIL DISTRIBUTION, NO DIRECT CONSUMER SALES ON LOCATION. THE <br />WHOLESALE IS OCCUPYING THE 2ND GARAGE BUILDING STRUCTURE ADJACENT TO THE <br />FAMILY MAIN HOME WITH AN ATTACHED GARAGE. NO RENOVATION IS REQUIRED, THE PRIOR <br />HOMEOWNER HAD OPERATED A PLUMBING BUSINESS OUT OF THE SAME GARAGE. <br />CODE ANALYSIS FOR: <br />14270 201ST AVE NW, ELK RIVER, MN 55330 <br />APPLICABLE CODES: <br />2020 MINNESOTA STATE BUILDING CODE <br />2020MINNESOTA ENERGY CODE 2016 ASHRAE 90.1 <br />2020 MINNESOTA ACCESSIBILITY CODE <br />2020MINNESOTA MECHANICAL AND FUEL GAS CODE <br />2020MINNESOTA PLUMBING CODE <br />2020MINNESOTA FIRE CODE <br />2020MINNESOTA ELECTRICAL CODE <br />2020MINNESOTA ELEVATOR AND RELATED DEVICES CODE <br />BUILDING CLASSIFICATION <br />A. <br />1. <br />• <br />2. <br />• <br />3. <br />• <br />• <br />4. <br />• <br />• <br />B. <br />BUILDING TYPE & CONSTRUCTION TYPE (IBC CHAPTER 5 & 6) <br />BUILDING CLASSIFICATION <br />EXISTING SINGLE FAMILY ATTACHED GARAGE AND DETACHED 2ND GARAGE <br />TYPE OF CONSTRUCTION <br />EXISTING TYPE VB <br />BUILDING HEIGHT <br />EXISTING HEIGHT AT DETACHED 2ND GARAGE ONLY: <br />12' FLOOR TO CEILING <br />BUILDING AREA <br />EXISTING DETACHED 2ND GARAGE ONLY: <br />ASSUMED 2,268 SQ. FT. <br />OCCUPANCY GROUP (IBC CHAPTER 3) <br />1. GROUP: - F-2, LOW-HAZARD FACTORY INDUSTRIAL USE <br />PROPOSED AREA- 636 SQ. FT. <br />2.GROUP:- S-2, LOW-HAZARD STORAGE USE <br />PROPOSED AREA- 1343 SQ. FT. <br />TOTAL SQ. FT:- 1,979 SQ. FT <br />EXITING <br />A. DESIGN OCCUPANT LOAD (IBC 1004.1) <br />1. TOTAL OCCUPANTS- 10 OCCUPANTS <br />B. EXIT <br />1. NUMBER REQUIRED= 1 <br />2. NUMBER PROVIDED = 2 <br />3. NUMBER ACCESSIBLE REQUIRED= 1 <br />4. ARRANGEMENT (IBC 1015.2.1) <br />5. TRAVEL DISTANCE MAXIMUMS <br />- EXIT ACCESS (IBC 1017.2)= 150' MAX. <br />- COMMON PATH OF EGRESS= 75' MAX. <br />6. WIDTH (GRATER OR TWO CONFLICTING WIDTHS SHALL BE USED) <br />- DESIGN EXT WIDTH (IBC 1005.3) <br />- STAIRWAYS= N/A <br />- STAIRWAY (IBC 1009.4)= N/A <br />- CORRIDORS (IBC 1020.3.)= 36" MIN. <br />- EXIT PASSAGEWAYS (IBC 1024.2)= 36" MIN. <br />- EXIT DOORS (IBC 1010.1.1)= 32" MIN. CLR <br />7. DOORS <br />- SWINGS (IBC 1010.1.2) = N/A <br />- LANDINGS (IBC 1010.1.5)= NOT LESS THAN 44" <br />- THRESHOLDS (IBC 1010.1.6)= NOT EXCEED 3/4" ABOVE FINISHED FLOOR <br />PLUMBING FIXTURES <br />1. <br />A. NUMBER OF FIXTURES REQUIRED (IBC TABLE 2902.1) <br />BASE ON 10 OCCUPANCY. THE OCCUPANT LOAD SHALL BE DIVIDED IN HALF AND <br />APPLY THE FOLLOWING PER IBC 2902.1.1. (1) TOILET PER 100 MALES AND (1) TOILET <br />PER 100 FEMALES. (1) SINK (LAVATORIES) PER 100 MALES AND (1) SINK (LAVATORIES) <br />PER 100 FEMALES. (1) DRINKING FOUNTAIN PER 500 OCCUPANTS OR SIMILAR, WATER <br />DISPENSER. <br /> <br />- 5 FEMALE OCCUPANTS (5 / 100 = 0.05) <br />- WATER CLOSETS REQUIRED = 0PROVIDED = 1 <br />- LAVATORIESREQUIRED = 0PROVIDED = 1 <br />- 5 MALE OCCUPANTS (5 / 100 = 0.05) <br />- WATER CLOSETS REQUIRED = 0PROVIDED = 0 <br />- LAVATORIESREQUIRED = 0PROVIDED = 0 <br />- OTHERS <br />- URINAL REQUIRED = 0PROVIDED = 0 <br />OTHERS <br />A. ACCESSIBILITY (IBC - CHPT. 11) <br />DEFERRED PLAN SUBMITTALS <br />A. COORDINATION WITH ENGINEER AND CONSULTANT ARE NOT PROVIDED AND PART OF <br />SCOPE OF THE ARCHITECT AT THIS TIME. <br />1. <br />2. <br />A. <br />FIRE PROTECTION <br />FIRE EXTINGUISHERS 75' MAX. TRAVEL DISTANCE (MBC TABLE 906.3) <br />FIRE SPRINKLED <br />EXISTING STRUCTURE- NOT SPRINKLER <br />LEGEND <br />ACCESSIBLE MEANS OF EGRESS <br />EXIT <br />EXIT ACCESSEXITEXIT <br />EXISTING WALL <br />NEW <br />PATH OF TRAVEL <br />BOUNDARY OF AREA <br />FIRE EXTINGUISHERFE <br />PROJECT LOCATION: <br />PROJECT ADDRESS: <br />14270 201ST AVE NW, ELK RIVER, MN 55330 <br />MAIN HOME WITH <br />ATTACHED GARAGE <br />ARCHITECT:KERRIK WESSEL <br />1148 OAKCREST AVE <br />ROSEVILLE, MN 55113 <br />651-484-9190 <br />KERRIKWESSEL@GMAIL.COM <br />CHEE THAO <br />2748 MCKNIGHT ROAD NORTH <br />N. SAINT PAUL, MN 55109 <br />414-232-5819 <br />THAOCHEEL@GMAIL.COM <br />OWNER/ TENANT:BENJAMIN GOMEZ <br />14270 201ST AVE NW, <br />ELK RIVER, MN 5330 <br />612-205-5705 <br />BENJAMIN.GOMEZ12@GMAIL.COM <br />GENERAL CONTRACTOR:N/A <br />PROJECT TEAM <br />RevDescriptionDateI hereby certify that this plan, specifications or report was <br />prepared by me and under my direct supervision, and that <br />I am a dully Licensed Architect under the laws of the State <br />Mennesota. <br />Printed Name: <br />Signature: <br />Date: Licensed #: <br />Scale: As indicated <br />Project #: 25-0316 <br />A1EL ROJO WHOLESALE <br />14270 201ST AVE NW, ELK RIVER, MN 55330 <br />Drawn By: CT <br />Checked By: KW <br />COVER <br />INFORMATION <br />KERRIK WESSEL <br />4593003/25/25 <br />Approved By: BG <br /> 1/4" = 1'-0" <br />LEVEL 1 - CODE PLAN <br />EL ROJO WHOLESALE <br />14270 201ST AVE NW, ELK RIVER, MN 55330 <br />SHEET INDEX <br />SHEET NO.SHEET NAME <br />ARCHITECTURAL <br />A1COVER INFORMATION <br />A2FLOOR PLAN - LEVEL 1 <br />A3FLOOR PLAN - FF&E <br />A4REFLECTED CEILING PLANS <br />A5DETAILS <br />FRONT ELEVATION <br />Page 158 of 197
The URL can be used to link to this page
Your browser does not support the video tag.