My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6.1g ERMUSR 03-12-2024
ElkRiver
>
City Government
>
Boards and Commissions
>
Utilities Commission
>
Packets
>
2014-2024
>
2024
>
03-12-2024
>
6.1g ERMUSR 03-12-2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2024 9:28:17 AM
Creation date
3/12/2024 3:12:56 PM
Metadata
Fields
Template:
City Government
type
ERMUSR
date
3/12/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Follow-up flags indicating that Purchaser should investigate situations found at a premise <br />7.16 <br />such as incorrect data, safety issues, potential tamper, premise repairs required, date/time <br />5,010 <br />found, Purchaser's parry reported to, and other situations found in the field by the Supplier. <br />No Charge <br />Comments section is to include the correct versus incorrect data found and note follow-up <br />7.17 <br />flag details. <br />5,010 <br />No Charge <br />7.18 <br />Premise as -found condition (based on list to be provided by Purchaser). <br />5,010 <br />No Charge <br />7.18 <br />Premise as -left condition (based on list to be provided by Purchaser). <br />5,010 <br />No Charge <br />7.19 <br />Certification that locks and seals are in place - Y/N. <br />5,010 <br />No Charge <br />7.20 <br />Digital photograph of the as -found meter/meter read. <br />5,010 <br />No Charge <br />7.21 <br />Digital photograph of the empty water meter can with meter removed. <br />5,010 <br />No Charge <br />7.22 <br />Digital photograph ofthe as -left meter/meter read. <br />5,010 <br />No Charge <br />7.23 <br />- If repair required, a digital photograph of the water meter with the meter removed <br />5,010 <br />No Charge <br />revealing <br />Defective Plumbing: The Supplier shall promptly notify the Purchase if defective plumbing is <br />7.24 <br />found that could prevent a safe meter change. If the Purchaser concurs, the installation will <br />5,010 <br />be deferred until repairs are made and the installer informed of the repair. <br />No Charge <br />Effective Shut -Off: The first valve is defined as the upstream shutoff valve or the valve on the <br />street side of the meter. The second valve is on the downstream side of the meter. The curb <br />stop valve is located in the street right-of-way and shall be operated by Purchaser. The <br />installer shall operate the first valve to obtain the shut-off necessary for meter installation: <br />however, should the first valve be defective, the installer shall freeze the service connection <br />upstream of the first valve to obtain the shut-off. Freezing shal I be accomplished with the use <br />725 <br />of CO2 freeze packs, electrical freeze units, or dry ice. The installer shall freeze the service <br />TBD <br />connection to accomplish shut -offs for accounts with inoperative first valves, at the <br />customer's first scheduled appointment without having to reschedule. I n cases where freezing <br />cannot be employed to obtain the shut-off the meter installer shall inform the Purchaser to <br />close the curb stop valve. Purchaser owns the curb stop and is responsible for repairing buried <br />or broken curb stops. The installer shall note any plumbing problems on the installation record <br />Additional Charge for Freeze shut <br />form. <br />$ 117.12 <br />off only <br />Supplier Leak Testing: After the installation of the metering system is complete, the installer <br />shall open all valves and check for leaks. The installer shall verify that the meter register is <br />functioning properly and that the meter and plumbing connections in the vicinity of the meter <br />726 <br />do not leak. All leaks or defects shall be repaired. It shall be presumed that any leaks in the <br />010 <br />vicinity of the water meter reported by the customer to either the Purchaser or the Supplier <br />within 90 calendar days after completion of the installation work at the customers property <br />are the result of the installation work. The Contractor shall repair such leaks and correct all <br />damages which occur during the 90-day period, at the Contractors expense. <br />No Charge <br />Approach: Please describe your proposed approach, at the minimum the installer should <br />turn on the water at the customers hose bib to ensure water is flowing, the installer should <br />727 <br />flush out any sediment in the line. Then the installer should check for any leaks on the inlet <br />5,010 <br />and outlet side of the meter. <br />No Charge <br />Warranty: Any leaks found within 90-days of the installation date must be covered by the <br />7.28 <br />Supplier's warranty. Any leaks from the outlet side of the meter back to the utility <br />5.010 <br />curbstop/shut-off valve are obviously the responsibility of the installer (or utility <br />No Charge <br />Total Add -on Services Priced Incrementally <br />$ <br />Installation Incremental Services for AMI Module Retrofit with Existing Meter <br />Retrofit Incremental Installation Services (if any of these are included <br />Premise <br />Incremental <br />Optional vendor <br />S <br />in your base quote, then insert $0 in the cost cell) <br />Quantity <br />Add -on Service <br />Extended Cost <br />Clarification Comments <br />8.1 <br />ID of the installer. <br />582 <br />No Charge <br />8.2 <br />Date/time the order is completed. <br />582 <br />No Charge <br />8.3 <br />Read from the removed water meter register. <br />582 <br />No Charge <br />Read from the new water meter register. The reading from the water meter being installed <br />582 <br />8.4 <br />is expected to be zero. <br />No Charge <br />8.5 <br />Confi rm serial number of existing water meter. <br />582 <br />No Charge <br />8.6 <br />Media Access Control (MAC) or IP address, if present, of the AMI endpoint being installed. <br />582 <br />No Charge <br />8.7 <br />Confirm/document manufacturer of the existing meter body. <br />582 <br />No Charge <br />Follow-up flags indicating that Purchaser should investigate situations found at a premise <br />such as incorrect data, safety issues, potential tamper, premise repairs required, date/time <br />582 <br />found, Purchaser's parry reported to, and other situations found in the field by the Supplier. <br />8.8 <br />No Charge <br />217 <br />
The URL can be used to link to this page
Your browser does not support the video tag.