Remove and Replace Section 02630 (PIPE SEWERS — STORM), Part 2.2.D.1 with: <br />1. Chimney Seals shall be installed on all storm manholes and catch basins as directed by the <br />Engineer. Interior chimney seals shall only be installed when exterior chimney seals are <br />not feasible. The following brands are listed as standard of quality: <br />(a) Infi-Shield <br />(b) Cretex <br />(c) Strike Products I & I Barrier <br />(d) Eull's Manhole Shield <br />Add to Section 02705 — (MANHOLES, CATCH BASINS & VALVE BOXES — ADJUST CASTING), Part <br />1.2.A: <br />4. Payment for Remove and Replace Valve Box shall be paid at the contract price per Each <br />(EA), which shall be payment in full for all costs of labor, materials, and equipment to <br />remove and replace valve box. Also included in the price is all associated backfill, class 5 <br />aggregate base, bituminous patching, and all other necessary work. <br />5. Payment for Seal Drainage Structure (Manhole Chimney Seal) and Seal Drainage Structure <br />(Catch Basin Chimney Seal) shall be paid at the contract price per Each (EA), which shall <br />be payment in full for all costs of labor, materials, and equipment to install chimney seals <br />on structures designated by the Engineer. <br />Add to Section 027050 — (MANHOLES, CATCH BASINS & VALVE BOXES — ADJUST CASTING), <br />Part 2: <br />Chimney Seals shall be installed on all structures as directed by the Engineer. Interior <br />chimney seals shall only be installed when exterior chimney seals are not feasible. The <br />following brands are listed as standard of quality: <br />(a) Infi-Shield <br />(b) Cretex <br />(c) Strike Products I & I Barrier <br />(d) Eull's Manhole Shield <br />Page 13 <br />