<br />EXHIBIT D <br />FACILITY OPERATING PARAMETERS & <br />UTILITY SAVINGS CALCULATION METHODS <br /> <br />STANDARD OF SERVICE AND COMFORT <br />Space temperature set points for locations served by new controls and programmable thermostats will be set <br />and maintained by Client as shown in the tables below. CONTRACTOR shall not be responsible for existing HVAC <br />equipment (HVAC equipment not replaced as part of project) ability to meet the space temperatures provided in <br />the following tables. For locations where CONTRACTOR is installing new HVAC equipment all new equipment <br />shall provide space comfort conditions during the applicable warranty period as specified in the individual FIM <br />Scope of Work provided in Exhibit A. <br /> <br />Operating Schedule: City Offices: <br /> The building is generally occupied from 7:30 AM to 5:00 PM (Monday – Friday) during the year. <br /> Council Chambers is generally occupied from 7:30 AM to 5:00 PM (Monday – Friday) with two nights a <br />week for 6 additional hours as needed. <br /> <br />All time ranges not specified in the above statement will be assumed as un-occupied for purposes of energy <br />calculations and the standards of comfort. For the lighting savings, specific hours are as noted in the <br />calculations. <br /> <br />Calculation are based upon additional hours above the noted open / occupied hours for additional opening / <br />cleaning staff time. <br /> <br />General Building: <br />Space Maximum Temperature <br />Occupied 68°F <br />Unoccupied 62°F <br />Storage area requiring heat 40 deg F, except where existing use does not permit <br />Areas not requiring heat Minimum temperature required to prevent damage to th <br />facility. <br /> <br />Cooling Set Points: <br />Space Minimum Temperature <br />Occupied 74°F <br />Unoccupied N/A {no cooling during unoccupied periods\] <br />Storage area requiring cooling N/A <br />Areas not requiring cooling N/A <br />EXHIBIT D Page 26 of 27 <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.