12.25 47,776.87
<br />D2010 Plumbing Fixtures 2.10 8,177.71
<br />0.84 3,274.34
<br />0.14 535.14
<br />0.26 1,010.33
<br />0.57 2,218.10
<br />0.29 1,139.80
<br />D2020 Domestic Water Distribution 0.60 2,323.31
<br />0.60 2,323.31
<br />D3050 Terminal & Package Units 17.35 67,680.41
<br />17.35 67,680.41
<br />D4010 Sprinklers 3.71 14,480.01
<br />1.64 6,388.66
<br />1.80 7,017.55
<br />0.28 1,073.80
<br />D4020 Standpipes 1.02 3,979.37
<br />0.55 2,149.47
<br />0.47 1,829.90
<br />D5010 Electrical Service/Distribution 19.03 74,204.40
<br />4.91 19,149.56
<br />6.36 24,786.10
<br />7.76 30,268.74
<br />D5020 Lighting and Branch Wiring 13.64 53,205.52
<br />4.98 19,432.80
<br />0.34 1,335.20
<br />0.62 2,435.28
<br />1.35 5,260.87
<br />6.34 24,741.37
<br />D5030 Communications and Security 6.24 24,342.51
<br />1.68 6,534.48
<br />2.10 8,199.67
<br />0.65 2,539.97
<br />1.81 7,068.39
<br />Fire alarm command center, addressable with voice, excl. wire & conduit
<br />Internet wiring, 8 data/voice outlets per 1000 S.F.
<br />Communication and alarm systems, fire detection, addressable, 50 detectors,
<br />includes outlets, boxes, conduit and wire
<br />Wet standpipe risers, class III, steel, black, sch 40, 4" diam pipe, 1 floor
<br />Wet standpipe risers, class III, steel, black, sch 40, 4" diam pipe, additional
<br />floors
<br />Overhead service installation, includes breakers, metering, 20' conduit & wire,
<br />3 phase, 4 wire, 120/208 V, 1000 A
<br />Feeder installation 600 V, including RGS conduit and XHHW wire, 1000 A
<br />Switchgear installation, incl switchboard, panels & circuit breaker, 120/208 V,
<br />3 phase, 1200 A
<br />Receptacles incl plate, box, conduit, wire, 16.5 per 1000 SF, 2.0 W per SF, with
<br />transformer
<br />Miscellaneous power, 1.2 watts
<br />Central air conditioning power, 4 watts
<br />Motor installation, three phase, 460 V, 15 HP motor size
<br />Fluorescent fixtures recess mounted in ceiling, 1.6 watt per SF, 40 FC, 10
<br />fixtures @32watt per 1000 SF
<br />Telephone wiring for offices & laboratories, 8 jacks/MSF
<br />Standard High Rise Accessory Package 3 story
<br />Hydraulic passenger elevator, 3000 lb, 3 floors,12' story height, 2 car
<br />group,125 FPM
<br />Water closet, vitreous china, bowl only with flush valve, wall hung
<br />Urinal, vitreous china, wall hung
<br />Lavatory w/trim, vanity top, PE on CI, 20" x 18"
<br />Service sink w/trim, PE on CI,wall hung w/rim guard, 24" x 20"
<br />Water cooler, electric, wall hung, wheelchair type, 7.5 GPH
<br />Gas fired water heater, commercial, 100< F rise, 100 MBH input, 91 GPH
<br />Rooftop, multizone, air conditioner, offices, 25,000 SF, 79.16 ton
<br />Wet pipe sprinkler systems, steel, light hazard, 1 floor, 5000 SF
<br />Wet pipe sprinkler systems, steel, light hazard, each additional floor, 5000 SF
<br />Elk River TH 10 and Lowell Redevelopment TIF Analysis
<br />LHB Project No. 180477 Page 3 of 4
<br />Replacement Cost Report
<br />Parcel W, Antique Store
|