Laserfiche WebLink
2. Light and Ventilation <br /> a. HVAC system does not meet mechanical/building code. <br /> 3. Fire Protection/Adequate Egress <br /> a. Current wood handicap ramp lacks code-compliant protective handrails. <br /> b. Replace entrance door hardware with code-compliant egress style. <br /> c. Rear entrance concrete steps are not level with door threshold as per code. <br /> d. There is no code-compliant emergency egress window in basement to provide secondary <br /> exit. <br /> e. R3 Residential Group classification requires automatic fire sprinkler system building-wide. <br /> 4. Layout and Condition of Interior Partitions/Materials <br /> a. Interior walls and ceilings should be repaired/repainted. <br /> b. Exposed copper piping should be attached to walls. <br /> c. Kitchen casework should be painted. <br /> d. Baseboard should be replaced where missing. <br /> e. Door trim should be installed. <br /> f. Water stained floor should be re-sanded and finished. <br /> g. Miscellaneous debris should be removed from basement. <br /> h. Ceiling tile should be replaced in basement. <br /> i. Basement fire place brick should be cleaned. <br /> 5. Exterior Construction <br /> a. Wood soffits and eaves on rear of house need to be painted/covered to prevent water <br /> intrusion. <br /> b. Wood windows need to be painted and caulked to prevent water intrusion. <br /> c. Wood siding on rear of house is peeling and needs to be painted to prevent water intrusion. <br /> Description of Code Deficiencies <br /> 1. Current wood handicap ramp lacks code-compliant protective handrails. <br /> 2. Replace entrance door hardware with code-compliant style. <br /> 3. Replace non-compliant rear entrance concrete steps level with threshold per code. <br /> 4. Wood soffits and eaves on rear of house need to be painted/covered to prevent water intrusion. <br /> 5. Wood windows need to be painted and caulked to prevent water intrusion. <br /> 6. Wood siding on rear of house needs to be painted to prevent water intrusion. <br /> 7. Replace non-compliant forced air heating system and controls to meet code. <br /> 8. Modify non-compliant basement bathroom per code. <br /> 9. Replace non-complaint ceiling mounted gas heater located in attached garage to meet code. <br /> 10. Provide AFCI protected receptacles per code. <br /> 11. Provide GFCI protected receptacles in Kitchen. <br /> 12. Repair non-compliant basement wall outlets that are loose and have unprotected wiring. <br /> 13. Repair electrical outlets adjacent to main electrical panel that are damaged and are not code <br /> compliant. <br /> 14. Install code-required automatic fire sprinkler system. <br /> 15. Install code-required basement emergency egress window. <br /> Beaudry Redevelopment TIF District#24 Page 2 of 3 Building Report <br /> LHB Project No. 170323 Parcel F, Residence <br />