Laserfiche WebLink
GENERAL STANDARDS / FABRICATION & INSTALLATION <br />Fabrication & installation of the work to be <br />provided in these drawings must meet the <br />following conditions and specifications. <br />GENERAL <br />The requested work will comply with all Federal <br />and State codes, laws and regulations, and all <br />municipal ordinances or regulations In effect at <br />the time work is being performed. <br />Any alternates or changes to materials, <br />construction methods and sign types specified in <br />this document must be approved in writing by <br />City of Elk River or client's representative prior to <br />Implementation. <br />LABOR <br />GENERAL <br />Any work required under this section, that is not <br />specified in detail, shall be constructed In <br />accordance with approved shop drawings. <br />All work shall be fabricated & erected square, <br />plumb, straight & true. Cut-out letters, numbers & <br />images shall be cut in continuous, even lines as <br />indicated on drawings. Fabricator shall provide <br />all supporting & anchoring means as required for <br />proper installation. Fabricator is responsible to <br />provide proper thickness to eliminate waviness or <br />other deformations in materials. <br />EXPOSED METAL SURFACES <br />Exposed metal surfaces shall be reinforced, <br />braced & securely fastened to provide rigid <br />assembly. Sign faces shall be free of all holes, <br />except those required to Install letters or <br />weep -holes. Service access doors shall be <br />concealed wherever possible. Flush -butt locked <br />seams and fillers shall be metal screwed & bolted <br />on filler edges to provide smooth faces, free of <br />unsightly rivets. All steel Items exposed to the <br />weather, and all other steel items as written, shall <br />be galvanized or ground & painted with <br />zinc -chromate primer & finish coated. <br />EXPOSED JOINTS <br />Exposed joints shall be continuously welded, <br />ground & polished smooth and shall not be <br />visible. Mitered corners shall be snug, neat & <br />tight fitting in an even, smooth plane. <br />EXTERIOR & INTERIOR CABINETS AND FRAME <br />Exterior cabinets & frames shall be fastened with <br />stainless steel screws. Phillip -type, flat head, <br />countersunk screws or nuts & bolts shall be used <br />as indicated. The Interior cabinet on exterior <br />signage shall be rain -proof and painted white. <br />Signs shall be provided with weep -holes in <br />bottom, sufficient size to allow for proper <br />drainage per the cabinet size. <br />LABOR (continued) MATERIALS (continued) <br />ACCESSORIES, ANCHORAGE, MOUNTING FLEXIBLE MATERIALS <br />DEVICES & SPACERS <br />Accessories, anchorage, mounting devices & <br />spacers shall be guaranteed non -staining to <br />adjacent walls and sign finishes for a period of <br />five years after acceptance. Ferrous mountings <br />may be sleeved with non-ferrous metal covers <br />matching adjacent finishes, cemented with <br />non -hydroscopic glue, or other suitable <br />protective measures may be proposed to <br />comply with this specification. All aluminum that <br />Is in contact with ferrous metals shall be <br />separated with a heavy coating of bitumastic <br />paint or sheet neoprene. <br />INSTALLATION <br />All signs shall be installed as indicated on the <br />location drawings unless otherwise directed by <br />VISUAL Communications. Signs shall be secured <br />with hardware as indicated on these drawings or <br />methods as approved on shop drawings showing <br />alternative methods. Survey of ground <br />conditions relating to soil content, density & <br />compaction are the responsibility of the installing <br />company and must be included in the initial bid. <br />Removal and/or replacement of asphalt, <br />concrete, existing footings and poles are the <br />responsibility of the Installer unless otherwise <br />written on these drawings. <br />MATERIALS <br />GENERAL <br />All materials, used In production, shall be new <br />and of top quality, and free of defects impairing <br />strength, durability or appearance. <br />METALS <br />Thickness, size, type & seam placement must be <br />as written on drawings. <br />Steel sheet must be paint -lock or galvanized. All <br />edges of metal or aluminum shall be cut in a <br />continuous line and sanded smooth to finish. <br />Aluminum sheet to be #5052 alloy. All seams to <br />be straight & symmetrical. <br />PLASTICS <br />All fabrication and adhesives to be per highest <br />quality industry standards. All adhesive to be <br />nonstaining and warranted for the life of the <br />product. <br />Thickness, color, size, seam placement, seam <br />construction, depth of pillowed faces and brand <br />name as written on these drawings. <br />Embossed or flat sheet plastic shall be free of <br />wrinkles or imperfections from forming or <br />fabrication. All surfaces shall be free of scratches <br />Thickness, color, size, and brand names shall be <br />as written on drawings. <br />All fastening devices must meet dealer <br />recommendations. Seam placement shall be as <br />documented in drawings, straight and <br />symmetrical. Face surface shall be free of <br />wrinkles, discoloration & imperfections. Flexible <br />face to be of a tensile strength to withstand 120 <br />lbs. per square foot of wind pressure (UL - 48 <br />testing). <br />COATINGS & FINISHES <br />All aluminum, metal & fasteners shall befinish <br />coated with an appropriate primer & color coat <br />With corrosion Inhibitors guaranteed for ten 10 <br />g f) <br />years against fading, chipping, cracking, peeling <br />& discoloration. Fabricator to provide paint <br />warrantee from selected fabrication for 10Ye ar <br />warrantee on a 3 year basis. <br />Colors shall meet specifications on drawings. <br />Sample colors shall be furnished by fabricator for <br />approvals by VISUAL Communications, <br />All flexible face coatings shall be guaranteed for <br />eight (8) years against fading, discoloration & <br />mildew, provided that routine six month cleaning <br />and maintenance has been performed by an <br />approved sign representative. <br />All holes, cut edges & penetrations of prefinished <br />metals and aluminum shall be free of buns, <br />primed & brush painted to maintain a corrosion <br />proof finish. <br />ELECTRICAL <br />Electrical parts & materials shall meet all national <br />electrical codes, applicable local codes & the <br />requirements of the Underwriter's Laboratory, Inc. <br />and be labeled as such. All electrical parts shall <br />be new & free of defects. <br />Signs shall be completed with all necessary <br />lamps, tubes, ballasts, transformers, sockets and <br />internal wiring as required In these drawings and <br />to provide complete operable units, <br />Electrical service shall be provided as written in <br />these drawings. Extensions of wiring, conduit, <br />transformation of voltages if required, and final <br />connection are as noted in these drawings. <br />Verity exact location of existing stubs & junction <br />boxes by referencing drawing and site. <br />All signs shall provide evenly distributed lighted <br />surface equal to intensity specified. All areas of <br />lighted letters shall be of equal intensity in all <br />parts of the sign. <br />ELECTRICAL Icontinued) <br />All light sources shall be 'outdoor type', 30 Ma or <br />60 Ma transformers and/or 800 Ma ballasts rated <br />for -20F. <br />Proper disconnect switches shall be provided as <br />noted. Location shall be Inconspicuous & <br />approved by VISUAL Communications or <br />City of Elk River. <br />SHOP DRAWINGS FOR CHANGES OR ALTERNATES <br />Three 13) copies of shop drawings Indicating <br />changes or alternates in detail shall be submitted <br />to VISUAL Communications or City of Elk River. <br />Written approval of shop drawings shall be <br />required before any work is started on the section <br />being revised. <br />GUARANTEE & SERVICE <br />Contractor shall guarantee that all material and <br />work furnished in these <br />are drawings guaranteed <br />for one (1) year to be free of defects & faulty <br />workmanship, & that any defective material or <br />work shall be promptly repaired or replaced <br />without additional cost to the owner or their <br />consultant, Contractor shall, during the first year <br />of operation, fully maintain & service the signs, <br />making regular inspections, servicing, replacing <br />tubes & electrical equipment as necessary to <br />operate the signs without additional cost to the <br />client. Any guarantees for additional time or <br />services noted in these drawings are to be <br />included in the contract (le: 10 year point <br />warraniee) <br />l3�Ii391P]d <br />All exposed surfaces and sign components shall <br />be protected unfil final Installation and approval <br />by client or their consultant. Any work damaged <br />or discolored in any way before installation and <br />approval occurs shall be the responsibility of the <br />fabricator without additional cost to the owner or <br />their consultant. <br />CLEAN-UP <br />During the process of implementation, the <br />premises shall be kept reasonably free of all <br />debris & waste materials resulting from the work <br />being completed in this contract. Upon <br />completion and before final acceptance of <br />work, all debris, rubbish, leftover materials, tools <br />and equipment shall be removed from the site. <br />Final cleaning of all surfaces shall be carefully <br />done strictly in accordance with the <br />manufacturers or consultants instructions. <br />NOTES <br />Signs shall have noncorosve, concealed fasteners, <br />continuous v Icls, ground smooth, filed, primed & <br />finish painted to match. No visible attachment methods <br />or oil canning acceptable. <br />Appropriate weatherproof service access panels <br />required at strategic points for future servicing and <br />maintenance. <br />Weep holes w/ internal light shields required for all <br />Infernally illuminated sign cabinets and fabricated letters <br />forwaterdrainage. <br />Sign to meet all local, state & national codes. <br />Underwriters Laboratory (U.L.) label required. <br />Fabricating sign company responsible for wind load <br />calculations for sign support & concrete standards <br />based on soil conditions & prevailing winds. <br />Final electrical connection to be made by licensed <br />electrician. <br />Field survey 9 of each sign location is required uired to <br />identify 120 volt service, or 277 volt service and access <br />avalabllNy. Owner and contracted sign company to <br />coordinate type of voltage to be used. Contracted sign <br />company to Idenfiy correct electrical plan in shop <br />drawings. <br />Owner to run electrical to within 3' of sign location. <br />Provide 8' leads for final connection. Sign company <br />to make final electrical connection fo sign, unless <br />otherwise specified. <br />No exposed conduit. <br />Type, placement & hook-up of iime clocks, photocells, <br />computerized time clocks, etc. by others. <br />Flush mount fum-off switch required, switch to face <br />away from street side, painted to match background <br />placed on. <br />Contracted sign company to provide color & material <br />samples for review, and written approval to VISUAL <br />Communications prior to fabrication. <br />Contracted sign company to provide shop drawings <br />and full size patterns for review and written approval <br />by VISUAL Communlcations prior to fabrication. <br />Field survey of each sign location prior to providing <br />bid for fabrication & installation. <br />All finishes to be as specified and carry a 10 year warrantee <br />All colors to be vertfied prior to fabrication. <br />Installing sign company will not altar natural ml <br />conditions (pave or tar) without verifying with owner. <br />Sign installer to check all falowing for easements and <br />placement of sign as determined; including water, gas, <br />electrical, telephone, sewer, cable &sprinklers. <br />All permits are the responsibility of the contracted <br />sign company. <br />Ciry of <br />Elk --- <br />River <br />Exterior Sign Design & <br />Standards Manual <br />r <br />1'I <br />VISUAL <br />Coan.,rasaaeo.rs <br />475 Cleveland <br />Avenue North <br />S u i If e 2 2 3 <br />Ivy Leagae Place <br />Sarni Paul <br />Mi ofa <br />5 5 n 1 5 a 4 <br />651-644-4494 <br />651-644-4289 <br />visvalcom m.com <br />Copyright® <br />nrn ongi.al design <br />ated by <br />V srl sU A L <br />commam—s— m.. <br />Il cannot be copied. <br />t ransi a rre d or <br />reproduced In any <br />form and shall <br />in the property <br />of v I s U A L <br />communicanons, <br />Inc. The release of <br />this design in whde <br />or In part shall require <br />qole v 1 t f en <br />ulhonzatlon from <br />V I S U A L <br />Communtc at io ns, <br />Incorporated <br />Pralect: 13.12.08 <br />Date: 03/24/15 cc <br />09/01 /15 cc <br />03/24116.. <br />Fa9-A 12 <br />