My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8.1. SR 03-07-2016
ElkRiver
>
City Government
>
City Council
>
Council Agenda Packets
>
2011 - 2020
>
2016
>
03-07-2016
>
8.1. SR 03-07-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2016 10:33:59 AM
Creation date
3/4/2016 9:29:15 AM
Metadata
Fields
Template:
City Government
type
SR
date
3/7/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Item # <br />Ref # <br />Code <br />Section <br />Days to <br />Correct <br />Violation <br />Remarks <br />Corrected/Day <br />s to Correct <br />Ensure that the means of egress illumination is <br />equipped and maintained with an emergency <br />Emergency lighting in Pool area <br />8 <br />986 <br />MSFC <br />1027.5.3 <br />0 <br />power system capable of providing 30 minutes <br />was not operational, repair or <br />corrected <br />2007 <br />as 6/28/11 <br />of illumination in the event of primary power <br />replace as needed. <br />loss. <br />Provide a key box in an approved and Provide Elk River Fire <br />9 <br />787 <br />MSFC <br />506.1 <br />0 <br />accessible location. Such key box shall be of Department with new keys for <br />corrected <br />2007 <br />an approved type and shall contain keys to gain <br />key box. <br />as 6/28/11 <br />access as required b the code official. <br />Provide annual inspection and testing of <br />sprinkler systems in accordance with Chapter 5 Provide documentation of annual <br />of NFPA 25 (02). The owner is responsible for automatic sprinkler system and <br />MSFC <br />this annual inspection and test of the sprinkler <br />fire pump testing. Testing was <br />corrected <br />10 <br />862 <br />2007 <br />901.6.1 <br />0 <br />system, which shall be completed by a licensed being conducting at time of <br />as 6/28/11 <br />sprinkler contractor employing licensed inspection but was not complete <br />journeymen sprinkler fitters pursuant to Minn. and no documentation provided. <br />Rules § 7512.2800, with all noted deficiencies <br />corrected <br />Provide periodic inspection and testing for all <br />fire protection systems and equipment <br />Provide documentation of annual <br />(including fire sprinklers, fire hydrants, <br />automatic fire alarm system <br />11 <br />863 <br />MSFC <br />901.6.1 <br />0 <br />standpipes, fire alarm, fire extinguishers, smoke <br />testing and inspections. No <br />corrected <br />2007 <br />and heat vents, smoke removal, and other fire <br />documentation available for <br />as 6/28/11 <br />protection appliances), with all noted <br />deficiencies corrected. Maintain documentation <br />review. <br />of inspection and testing for 3 years. <br />Provide periodic inspection and testing for all <br />fire protection systems and equipment <br />(including fire sprinklers, fire hydrants, <br />Fire extinguishers were last <br />12 <br />863 <br />MSFC <br />901. 6.1 <br />o <br />standpipes, fire alarm, fire extinguishers, smoke <br />serviced in 2009. Provide current <br />corrected <br />2007 <br />and heat vents, smoke removal, and other fire <br />as 6/28/11 <br />protection appliances), with all noted <br />service. <br />deficiencies corrected. Maintain documentation <br />of inspection and testing for 3 years. <br />Automatic sprinkler heads in <br />Replace all painted or damaged fire sprinkler <br />Sauna and Pool Chemical <br />13 <br />866 <br />MSFC <br />901.6 <br />0 <br />heads. All sprinkler work must be done by a <br />Room/Mechanical Room shall be <br />corrected <br />2007 <br />licensed contractor. <br />replaced. All heads in Pool area <br />as 6/28/11 <br />were replaced due to damacle. <br />Follow-up Inspection Remarks:This was a follow-up inspection prior to reopening in company of Elk River FD. All items were <br />corrected per orders issued. <br />Initial Inspection Remarks: <br />This was an inspection prior to reopening facility that has been closed for over 1 year. The above items shall be corrected prior to <br />opening. A re -inspection shall be conducted to verify corrections. NOTE: Provide Federal Tax ID to St Paul office prior to opening. <br />Previous Follow-up Inspection Remarks: <br />Appears to meet minimum requirements. <br />Owner/Representative: <br />Inspector: <br />John Gergen - (320) 654-0517 <br />A variance procedure is available. Please contact the inspector named for further assistance with this or any other matter. <br />Page 2of2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.