Laserfiche WebLink
Insp. No.: 28385 <br />Followup: 11 <br />State Fire Marshal Division <br />File No.: <br />RS -82184 <br />Orig. Insp. Date: <br />5/27/2011 <br />Minnesota Department of Public Safety <br />444 Cedar St., Suite 145 <br />St. Paul, MN 55101-5145 <br />"''' "„ 7�. <br />~� �xstr,at <br />Previous Insp. Date: <br />5/27/2011 <br />Insp. Date: <br />6/28/2011 <br />Insp. Time: <br />2.00 <br />Travel: <br />2.00 <br />Inspector: <br />Gergen, John W <br />Order <br />Property: Elk River Inn & Suites <br />Building: <br />Section: <br />Address: 17432 Hwy 10 <br />Elk River, MN 55330 <br />Contact: Contact Name/Phone: Pat Briggs 763-441-8554 <br />Contact E-mail: pat@thebriggscompanies.com <br />Property Phone: 612-441-8554 <br />Owner: Elk River Lodge and Suites <br />11110 Industrial Circle, Suite E <br />Elk River, MN 55330 <br />Contact: Contact Name/Phone: Kelly Anderson EXT 33 763-633-1080 <br />Contact E-mail: <br />Owner Phone: 763-633-1080 <br />Item # <br />Ref # <br />Code <br />Section <br />Days to <br />Correct <br />Violation <br />Remarks <br />Corrected/Day <br />s to Correct <br />Numerous extension cords were <br />MSFC <br />Remove extension cords that are being used as <br />being used at Breakfast Bar area. <br />corrected <br />1 <br />819 <br />2007 <br />605.5 <br />0 <br />a substitute for permanent wiring. <br />Provide approved permanent <br />as 6/28/11 <br />wiring for appliances. <br />Remove unapproved locking devices from exit <br />Remove double key deadbolt <br />MSFC <br />doors. Exit doors shall be openable from the <br />locks on doors from Pool to <br />corrected <br />2 <br />935 <br />2007 <br />1008. 1.8 <br />0 <br />inside without the use of a key or any special <br />Lobby. Provide approved locking <br />as 6/28/11 <br />knowledge or effort. <br />devices with egress hardware. <br />MSFC <br />Provide approved address numbers that are <br />Provide address numbers that <br />corrected <br />3 <br />786 <br />2007 <br />505.1 <br />0 <br />plainly visible from the street or road. <br />are visible from street. <br />as 6/28/11 <br />Electrical appliances and fixtures shall be <br />All appliances in Lobby/Breakfast <br />4 <br />821 <br />MSFC <br />605.7 <br />0 <br />installed and maintained in accordance with <br />Area shall be commercial listed <br />corrected <br />2007 <br />as 6/28/11 <br />their listings. <br />appliances - liances. <br />Single station smoke detection In <br />all guest rooms shall be <br />operational. Provide <br />documentation that all singe <br />Ensure that the required fire detection, alarm, <br />station detection has been tested <br />5 <br />861 <br />MSFC <br />901.5.1 <br />0 <br />and suppression systems have been tested and <br />or replaced. Have fire alarm <br />corrected <br />2007 <br />contractor provide sensitivity <br />as 6/28/11 <br />approved prior to occupancy of the building. <br />testing or replace detection. <br />Numerous rooms were not <br />accessible at time of inspection <br />and numerous detectors were <br />miccinn nr not nnaratinnal <br />Smoke detector sensitivity shall be checked <br />Provide documentation of <br />MSFC <br />after 1 year, then every other year. If found <br />sensitivity testing of fire alarm <br />corrected <br />6 <br />### <br />2007 <br />907.20.3 <br />0 <br />within range, sensitivity testing may be <br />components including heat <br />as 6/28/11 <br />extended to a maximum of 5 yrs. Nuisance <br />detection in corrosive areas. <br />alarm records must be available. <br />Provide approved self-closing and latching <br />Corridor door to Main Laundry <br />devices for required fire -rated doors. Such <br />was being held open with a non- <br />7 <br />837 <br />MSFC <br />703.2 <br />0 <br />doors may be held open by the use of approved <br />approved hold open device; if <br />corrected <br />2007 <br />door is to be held open shall be <br />as 6/28/11 <br />devices which release upon the activation of <br />magnetically with automatic fire <br />smoke detection or loss of power. <br />alarm for release. <br />Page 1 of 2 <br />