Laserfiche WebLink
Medical Professional Building/Phoenix Enterprises <br /> September 22,2004 Page 3 <br /> 3. Utility Plan <br /> • Sanitary sewer and water service will be provided by existing six-inch sewer and <br /> water services. According to City Ordinance Section 78-159, a sampling <br /> manhole will be required on the sanitary sewer service. This manhole should be <br /> placed in the bituminous paved parking lot drive aisle for ease of access. <br /> • Catch Basin #2 is located along a ramp in a handicap loading area. The curb in <br /> this area will most likely be depressed to create the ramp and will not be tall <br /> enough to provide a curb opening on the catch basin casting. The grate needs to <br /> be selected carefully to provide for safe wheelchair crossings. Perhaps a different <br /> location for the catch basin could be found. <br /> • The plan shows the existing fire hydrant to be relocated into an island along side <br /> the main driveway entrance. If this re-location work requires any shutdown of <br /> the existing watermain service to other buildings in the area, it will need to be <br /> coordinated so as not to disrupt normal business operations. A valve needs to <br /> be added to the hydrant lead after relocation. <br /> If you have any questions regarding any of these comments, please call. <br /> Sincerely, <br /> Terry J. Maurer,P.E. <br /> City Engineer <br /> S:\PLANNING\Case Files\2004\CU 04-27 Phoenix Entp\Engineers memo 9-22-04.dcc <br />