My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4.1 - 4.3 PCSR 06-11-2013
ElkRiver
>
City Government
>
Boards and Commissions
>
Planning Commission
>
Planning Packets
>
2011-2020
>
2013
>
06-11-2013
>
4.1 - 4.3 PCSR 06-11-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2013 10:01:28 AM
Creation date
6/7/2013 8:47:16 AM
Metadata
Fields
Template:
City Government
type
PCSR
date
6/11/2013
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PI1NEERengineering MENDOTA'HEIGHTS <br /> CORPORATE OFFICE .: <br /> 422 Enterprise Rrive <br /> CIVIL ENGINEERS LAND PLANNERS LAND SURVEYORS LANDSCAPE ARCHITECTS Mendota Heights,MN,55120 <br /> phone (651)681-1914, <br /> fax (651)681-9488• <br /> May 24,2013 <br /> Mr.Jeremy Barnhart <br /> City of Elk River <br /> 13065 Orono Parkway <br /> Elk River,MN 55330 <br /> Re: Kliever Lake Fields 4r1i addition: <br /> Preliminary and Final Plat <br /> Conditional Use Permit <br /> Zone Change <br /> Easement Vacation <br /> Dear Mr.Barnhart, <br /> Please find below our response to your review comments dated May 16,2013. <br /> Engineering/Water <br /> 1) All abandoned sewer mains in the public right of way should be sand filled and <br /> capped in the manholes in the street. <br /> Plans revised per comment. <br /> 2) The water lines serving the former buildings under the private drives are considered <br /> private. While not recommended,they may be abandoned in place. However,to <br /> avoid the cost of removing the public corp fitting in the street(and replacing a <br /> portion of the public street) that serves these private lines,the fire hydrants should <br /> be relocated to the edge of the ROW. <br /> Plans revised per comment. <br /> 3) There are concerns regarding water stagnation issues for lots that feed off of Outlot <br /> B and Outlot C. It is recommended that a connection be made between these two <br /> drives to address the water gnality concern. <br /> The amount of water and the time required to fully exchange the water in the <br /> main was calculated to determine if stagnant water would result in water <br /> quality issues. <br />
The URL can be used to link to this page
Your browser does not support the video tag.