My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4.4 PCSR 11-13-2012
ElkRiver
>
City Government
>
Boards and Commissions
>
Planning Commission
>
Planning Packets
>
2011-2020
>
2012
>
11-13-2012
>
4.4 PCSR 11-13-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2012 2:27:49 PM
Creation date
11/8/2012 1:31:46 PM
Metadata
Fields
Template:
City Government
type
PCSR
date
11/13/2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. <br /> <br />. There are notes referring to storm sewer to be removed just northeast of the existing <br />home. However, the existing storm sewer is not shown on this plan sheet. <br /> <br />C. Sheet 5 of 13 Site and Dimension Plan <br /> <br />. The north entrance onto 17yd Avenue should stop the curb at the plat boundary. <br />Extending curb onto 173rd Avenue which is a rural section would create a snowplow <br />hazard. <br />. There is no lighting shown on this plan. <br /> <br />D. Sheet 6 of 13 Site and Dimension Plan <br /> <br />. The one-inch copper water service shown for the existing home should be removed <br />along with the removal of the home. Elk River Municipal Utilities should be <br />contacted to verify the method of removal. <br />. This plan sheet should be revised to reflect the additional dedication of right of way <br />along 171 st Avenue in the location of the existing home to be removed. <br /> <br />E. Sheet 7 of 13 Grading and Drainage Plan <br /> <br />. <br /> <br />. Show the normal water level on all ponds. <br />. The north pond (12) lOa-year HWL is shown as 879.5 but the drainage calculations <br />show the HWL as 880.82. <br />. Show emergency overflow (EOF) of 880 between north pond (12) and east pond <br />(11). <br />. East pond (11) shows a lOa-year HWL of 879.5 but the drainage calculations show <br />the lOa-year HWL as 880.82. <br />. Show erosion blanket on all pond slopes according to NPD ES guidelines. Erosion <br />blanket must be placed within 7 days of completing work on pond slopes. <br />. The grading of the ponds as shown limits access to the existing sanitary sewer <br />manholes along the east property line. The City Sewer Department needs to access <br />these manholes with a large truck for annual sewer jetting. Revise the grading plan <br />to show truck access to all of the existing manholes. <br /> <br />F. Sheet 8 of 13 Grading and Drainage Plan <br /> <br />. <br /> <br />. Existing catch basin at south end of existing parking lot has 8.67 cfs flowing to it <br />which will exceed its inlet capacity. Install additional catch basins to meet the <br />required inlet capacity as needed. <br />. Silt fence along the south drive is shown off of the project site. <br />. Provide easement for south pond outlet pipe. <br />. South pond shows lOa-year HWL as 875.5 but the drainage calculations show the <br />lOa-year HWL as 879.6. Provide EOF swale from south pond to 171 st Avenue. <br />. Grade the area along the north boulevard of 171 st Avenue to provide 2 percent <br />positive slope towards the curb line. <br />. Is the power pole south of south pond to be removed? <br />. Change storm sewer layout to collect drainage at curb line south of the car wash by <br />sliding CBMH 107 south to the last parking stall. <br /> <br />S:\PLANNING\Case Files\Z006\Plat\P 06-06 ]abez\04 03 06 engr memo. doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.