A~.TICLL~ III. ~~L~I~'V~A~TE FA~ILITIES~
<br />spreading, compacting and other needs.
<br />Page l~ o~~~
<br />f. Proposed operating procedures, including consideration of each item identified in Minnesota
<br />Rules section 705. ~ 70~,
<br />~~ ~} Such additional information and data, including any additional environmental analysis, as maybe
<br />required by the city building and zoning administrator, the planning commission, or the city council.
<br />(Code 1982, § 604.26(2))
<br />~a ~~~'.rn~n~ur~ req~~rer~ena
<br />~a} ~'he following minimum requirements shall be established, constructed, provided and maintained at the
<br />sanitary landfill site;
<br />~~} ~ratection or~ublic heelfh, safety and weirare. ~"he sanitary landfill shall be sa situated, equipped,
<br />operated, and maintained as to minimize, to the maximum extent possible, using the best available
<br />technology, any potentially adverse impact on the public health, safety, and general welfare,
<br />~2} Interference with other uses. The sanitary landfill shall be so situated, equipped, operated, and
<br />maintained as to minimize impacts on, and interference with, other land uses and activities in the area,
<br />~3} ~.eachete collection systems. All sanitary landfills shall be equipped with a liner and leachate
<br />collection system adequate to called all leachate which may be generated afi the site, The city council
<br />shall also require leachate collection systems for existing solid waste deposits if, in ifs sole discretion, it
<br />is determined to be necessary for the protection of the public health, safety, and general welfare.
<br />I~eachate collected shall not be disposed of in the city, or in the city sewer system or sewage treatment
<br />plant, unless specific permission to do sa is granted by the city.
<br />~4~ employee shelter and sanitary facilities. Sanitary facilities and shelter shall be provided for site
<br />personnel.
<br />~5} ~.itter control. Litter control devices such as portable and permanent fences shall be provided,
<br />~~} electrical service. Adequate electrical service shall be provided at the site for operations and
<br />repairs.
<br />~7} dire cquipr~ent. Firefighting facilities an~site, adequate to ensure the safety of the public and
<br />employees, shall be provided,
<br />~~} Safcty equipment. emergency first aid equipment to provide adequate treatment for accidents,
<br />including those resulting from hazardous and toxic wastes, shall be provided.
<br />~9} Potable water sup~iy. A potable water supply for site personne! shall be provided.
<br />~~ ~} Storage facilities. Shelter for maintenance and storage of site operations equipment shall be
<br />pravided.
<br />~~ 1 } Vehicle stacking racilities. Adequate vehicle stacking faciiifiies must be pravided to ensure that no
<br />vehicle desiring entry into the site shall have to wait outside the perimeter of fihe sanitary landfill site,
<br />~~ ~} emergency communication facilities. Adequate Communication facilities shall be provided for
<br />emergency purposes.
<br />~~ 3} Security. Tha site shall be fenced and a gate shall be provided at the entrance to the site and
<br />kept locked when an attendant is not an duty.
<br />~~~} Maul roaa~. An all~weafiher haul road shall be pravided to the unloading area,
<br />~~ 5} ~'q~uiprnent, ~quipmenfi sufficient for spreading, compacting, and covering operations, to include
<br />sufficient reserve equipment or arrangements to immediately provide for equipment during periods of
<br />breakdown, shall be pravided,