My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5.1. SR 08-03-2009
ElkRiver
>
City Government
>
City Council
>
Council Agenda Packets
>
2000 - 2010
>
2009
>
08-03-2009
>
5.1. SR 08-03-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2009 10:22:23 AM
Creation date
7/31/2009 10:19:52 AM
Metadata
Fields
Template:
City Government
type
SR
date
8/3/2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Elk River Library <br /> <br />n~ <br />m p <br />v ~ <br />~ ~ <br />ro ~~ <br />a a <br />9 0 <br />1 0 <br />Regional Materials <br />Construction Application <br />Elk River Library <br />1 /18/2008 <br />Construction Application <br />Credit 5-Version 2.2 <br />2/3/2009 <br />The LEED Submittal Template and calculation have been provided stating that 15.69% of the total building <br />materials value is comprised of building materials and/or products that have been extracted, harvested or <br />recovered, as well as manufactured within 500 miles of the project site. <br />Rapidly Renewable Materials <br />Certified Wood <br />Credit 6-Version 2.2 <br />Credit 7-Version 2.2 <br />Minimum IAQ Performance <br />Design Application <br />Prerequisite 1-Version 2.2 <br />9/20/2007 <br />The LEED Submittal Template has been provided stating that the project has been designed to meet the <br />minimum requirements of ASHRAE Standard 62.1-2004, using the Ventilation Rate Procedure. <br />^o ^o Environmental Tobacco Smoke (ETS) Control <br />Prerequisite 2-Version 2.2 <br />Design Application 9/20/2007 <br />The LEED Submittal Template has been provided stating that smoking is prohibited within the building and <br />designated exterior smoking areas have been located at least 25 feet away from entries, outdoor air intakes and <br />operable windows. <br />^o Outdoor Air Delivery Monitoring Credit 1-Version 2.2 <br />Design Application 9/20/2007 <br />The LEED Submittal Template declares that a permanent C02 monitoring system has been installed in the <br />densely occupied spaces, that provides feedback on ventilation system performance to ensure that the <br />ventilation systems maintain design minimum ventilation requirements. The system is configured to generate <br />an alarm when the conditions vary by 10% or more from setpoint, via either a building automation system alarm <br />to the building operator or via a visual or audible alert to the building occupants. In addition, the applicant <br />provided information describing the direct air flow measuring device that serves the non-densely occupied <br />spaces. Drawings were also provided as supporting documentation. <br />Page 9 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.