Laserfiche WebLink
Isolated means a condition whereby the generating equipment is not <br />interconnected with ERMU's electric system. <br />Kilowatt (kW) means unit of electric power equal to 1000 watts. <br />Kilowatthour (kWh) means unit of electric energy equal to one kilowatt of power <br />supplied to or taken from an electric system steadily for one hour. <br />Parallel means a condition whereby the generating equipment is interconnected <br />with ERMU's electric system. <br />Sprin~/fall season means the period from March 1 through May 31, and <br />September 1 through November 30. <br />Summer means the period from June 1 through August 31. <br />Utili means Elk River Municipal Utilities or (ERMU) <br />Winter means the period from December 1 through February 28 or 29. <br />ARTICLE 2. TERM. This Agreement shall begin at 12:01 a.m. on <br />and shall continue until termination as provided for in Article 12. <br />ARTICLE 3. GENERATOR AVAILABILITY. Customer represents and warrants to <br />ERMU that the Customer Generator shall be available for operation upon request by <br />ERMU or its designated agent during the term of this Agreement. <br />ARTICLE 4. SAFETY AND OPERATING STANDARDS. Safety and Operating <br />Standards under which ERMU operates are imposed to protect ERMU employees and the <br />general public, and are intended to guarantee a quality of service to the other customers. <br />Customer must operate Customer Generator in a manner that insures the safety of ERMU <br />employees and the general public, and must allow electric service to other customers to <br />remain within prescribed limits. <br />Section 1: Inspection. An inspection certificate issued by the state electrical <br />inspector having jurisdiction at Customer location is required to assure wiring <br />complies with the IEEE, National Electrical Code, National Electric Safety Code, <br />and applicable local codes. An inspection by ERMU personnel is also required <br />prior to finalizing this Agreement. All Federal, State, and local safety codes <br />pertaining to installation, operation, and maintenance of Customer Generator and <br />collateral equipment shall be followed and are the responsibility of Customer. <br />Section 2: Safety Equipment. The following requirements apply to all <br />interconnected generating equipment. ERMU's Distribution System shall be the <br />source side and Customer Generator shall be the load side in the following <br />interconnection requirements. <br />