Laserfiche WebLink
Parking <br />(3) Parking has been calculated as one stall per 200 square feet (retail), which would require 105 <br />parking stalls for the proposed two buildings. Uses other than retail may generate additional parking. <br />The site plan indicates there are 143 stalls provided. Included in these spaces are portions of 43 <br />spaces on the city Right-Of-Way, in a proposed easement. Staff and the city attorney are reviewing <br />this proposal; The easement will make it clear that the applicant is responsible for maintaining the <br />parking stalls. <br />Item 3 -The applicant will be responsible for maintaining the parking spaces as described. <br />Architecture <br />(4) The site is designed to be consistent with the Elk River Crossing PUD architecture standards. The <br />prominent exterior materials include brick and E.I.F.S. To be consistent, buildings over 100 feet in <br />length should incorporate recesses, off-sets, pilasters or angular forms so that no uninterrupted <br />length exceeds 50 feet. The wall projection or recess should be a depth of about 3% of the length of <br />the uninterrupted building length. These requirements from the PUD agreement, apply to the front <br />and all facades visible from adjoining properties or public streets. Staff and the applicant have <br />worked together to develop a facade plan that meets the material requirements, although it is <br />unclear that the fagade relief is provided. <br />Item 4 - A114 elevations, on both buildings, have been designed with relief elements to meet your <br />architectural standards. <br />Signage <br />(5) Again to be consistent with the PUD, each tenant is allowed two wall signs. The applicant has <br />proposed a monument sign that is 30 feet in height. To be consistent with the Elk River Crossing <br />PUD, one monument is allowed for the site, with a maximum of 100 square feet and 10 feet in <br />height. The council can approve the height as proposed since this is a PUD. The monument sign is <br />proposed to be on the west side of the site, to be visible from Highway 169. Sign permits are <br />required for all signs. <br />Item 5 - A pylon sign addressing 169 is conceptually proposed. We are also conceptually <br />anticipating tenant signage for each tenant on the building addressing both Zane Street and 169, as <br />requested by each tenant. <br />Service Doors /Mechanical Equipment <br />(6) The submitted elevations indicate there will be service garage doors on the west side of the <br />building facing Highway 169. According to the PUD loading docks and mechanical equipment should be <br />incorporated into the overall design of the building and screened from view of adjoining properties and <br />streets. It should be noted that the building will use parapets to hide the roof top units. The overhead doors <br />cause some concern, as while they're prevalent in commercial settings, they cannot be screened using <br />landscaping, due to the power transmission lines. Staff would recommend no overhead doors for this <br />building. <br />Item 6 -The overhead doors are not necessary with "all" potential tenants but are shown due to the <br />interest of one potential tenant that has requested an overhead door. One thing to point out is that <br />the overhead doors shown wi[I match the adjacent doors in color, material, and canopy detailing. <br />They wilt not laok out-of-place but will be assimilated into the overall design concept and color <br />scheme. The traditional "Loading Dock" is not present in this design. <br />Landscaping <br />No Landscaping has been provided. A landscape plan, prepared by an architect will need to be approved <br />prior to release of a Building Permit. <br />I want you to remember that the site is encumbered with numerous easements and power <br />lines, limiting where we can place our structures. As the site exists, there are really no trees to <br />speak of. All trees are currently along Zane Street on City property and are small deciduous trees <br />