<br /> <br />SPACE PROGRAM FOR <br />ELK RIVER YMCA <br /> <br />DIMENSIONS: TED <br /> <br />SPACE FUNCTION:, Cardiovascular Fitness <br />Resis.tance Fitness Training <br />Strength Training <br /> <br />SPECIAL CONSIDERATIONS: <br /> <br />EQUIPMENT REQUIREMENTS: <br />Sound system <br />- Wall mounted TV's <br /> <br />ACCESS/ ADJACENCY NEEDS: View of pool ideal; views to <br />outside or other activity areas) fitness testing room (lO'x12'), <br />storage (10'xlS'), equipment repair (10'xlS'), fitness staff <br />office (1O'x12') <br /> <br />FLOOR FIN: Rubber at machine, interlocking rubber <br />at free weigh ts <br /> <br />WALL FIN: Mirrors a t free weigh ts <br /> <br />CEILING FIN: Ceiling tile; exposed structure <br /> <br />ACOUSTICAL REQUIREMENTS: <br /> <br />FITNESS AREA I <br /> <br />SQUARE FEET: <br /> <br />9,000 <br /> <br />OCCUPANTS: 60/70 s.f./Occupant <br />(Code: 180 @ 50 GSF /Occupant) <br /> <br />FLOOR LOAD: <br /> <br />B.\SE: <br /> <br />CEILING HEIGHT: 10' minimum <br /> <br />ELECTRICAL PO\X1ER: About 1/2 equipment needs power, some 220 V. Dedicated circuit, recessed floor <br />boxes with data capability, <br />LIGHTING: Fluorescent <br />FOOT CANDLES: 50 f/ c uniform coverage <br />TELEPHONE: Yes <br />COMMUNICATION: <br />SECURITY: <br />CONTROLS: Sensors <br />SOUND: Ceiling <br />HV AC: Perceptible air movement, 6-8 air changes/hour <br />PLUMBING: Drinking fountain, in space <br />OTHER: Emergency call button, docks <br /> <br />Origination Date: 2/6/07 <br /> <br />Modification Datc: <br /> <br />10 <br />