Laserfiche WebLink
<br />Background/Discussion <br />The applicant, Patrick Briggs, is proposing construction of a 59-unit multi-family apartment building at 17379 <br />Twin Lakes Parkway. The property is currently 5.79 acres in size and includes one single-family home on the <br />north side of the parcel. The current variance request supports the planned apartment building, but this <br />application does not authorize construction of the building. A separate administrative site plan review <br />application is required. <br /> <br />Proposed variances include a reduced parking requirement – reducing the required number of stalls from the <br />ordinance standard of 2.5 stalls/unit to 2.13 stalls. This type of parking request has become common <br />throughout the community, and a similar request was approved for the apartment building immediately north <br />of the subject site. <br /> <br />The proposed apartment building includes 53 studio units and 6 one-bedroom units. It is expected that this <br />unit style will reduce the parking demand below the 2.5 stalls/unit required within the ordinance and is <br />consistent with recent variances throughout the community. Staff included a typical requirement of an exhibit <br />demonstrating proof-of-parking to show that the full parking requirement can be met if parking becomes a <br />concern in the future. <br /> <br />The existing wetland on the property has been reviewed by the city’s environmental staff. The proposed <br />encroachment into the buffer/setback impacts 6 feet of the required 45-foot buffer and setback. Ordinance <br />prohibits structures and impervious surfaces in this area, but maintained vegetation (turf) is allowed. The <br />proposed building would be 39 feet from the delineated wetland and a small corner of the structure with a <br />smaller encroachment of 3-feet (42-feet from delineated wetland) for approximately 50 feet. <br /> <br />Civil plans include filling an existing wetland to accommodate the stormwater pond to treat the new <br />impervious surfaces. This impact is not part of the variance request and must be approved separately through <br />a wetland replacement plan. <br /> <br />Applicable Regulations <br />The variance standards are outlined below. The applicant's responses are noted in italics. <br />A variance may be granted when the petitioner establishes that the variance satisfies all five of the criteria <br />described below. <br /> <br />The variance is: <br />1. Is in harmony with the general purpose and intent of the ordinance, and <br /> <br />The zoning and Comprehensive plan are in alignment with owners use. <br /> <br />The parking variance has become a relatively common request either through a Planned Unit Development or <br />with a variance. The city’s experience with a parking variance of greater than 2 stalls/unit has generally not <br />resulted in too few parking stalls to serve the buildings. The included condition of a proof of parking exhibit <br />must show that additional parking can be constructed if parking becomes an issue in the future. <br /> <br />The wetland buffer setback has also become common, and with the condition that no additional impervious <br />surfaces be placed within the buffer setback, the impact is supported by staff. <br />The variances are generally in harmony with the purpose and intent of the ordinance. <br /> <br />2. Is consistent with the City of Elk River comprehensive plan. <br /> <br />The zoning and Comprehensive plan are in alignment with owners use. <br /> <br />The Comprehensive Plan guides the property for mixed-residential uses, up to and including small-scale <br />Page 52 of 97