Laserfiche WebLink
EXIT SIGNS <br />• Exits and exit access doors shall be marked by an approved exit sign readily visible from any <br />direction of egress travel. (Section 1013.1) <br />• Exit signs are not required in rooms or areas that require only one exit or exit access. (Section <br />1013.1, Exception #1) <br />• Exit signs shall be internally or externally illuminated. (Section 1013.1) <br />• Illuminated exit signs required at both exit doors out of larger space only. <br />• Illuminated exit sign recommended at exit access door out of smaller space. <br />EXIT ACCESS <br />• Means of egress are not prohibited through adjoining or intervening rooms or spaces in a <br />Group S occupancy where the adjoining or intervening rooms or spaces are the same or a <br />lesser hazard occupancy group. (Section 1016.2, Item #2 Exception) <br />• Smaller space egress passes through larger space. OK. <br />TRAVEL DISTANCE <br />• Group S-1, non-sprinklered. <br />• Exit access travel distance = 200 feet. (Table 1017.2) <br />• Actual =180 feet. OK. <br />PLUMBING FIXTURES <br />• Minimum number of required plumbing fixture. (Table 2902.1) <br />• Group S-1, 14 occupants. <br />• Water Closet, 1 per 100 occupants. <br />• Separate facilities [for each sex] shall not be required in structures or <br />tenant spaces with a total occupant load, including both employees <br />and customers, of 25 or less. (Section 2902.2, Exception #2) <br />• One water closet required. <br />• Bathtubs/Showers. <br />• Bathtub/shower not required. <br />• Lavatories, 1 per 100 occupants. <br />• One lavatory required. <br />• Drinking Fountains, 1 per 1,000 occupants. <br />• A drinking fountain shall not be required in buildings or tenant spaces <br />having an occupant load of less than 50. (Table 2902.1, Footnote H) <br />• Drinking fountain not required. <br />• Service Sink. <br />• One service sink required. <br />5 OF 5, PRINTED 7/5/2023 <br />PageW52A)872 <br />