My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Planning Commission Packet - May 28, 2024
ElkRiver
>
City Government
>
Boards and Commissions
>
Planning Commission
>
Planning Packets
>
2021-2030
>
2024
>
05-28-2024
>
Planning Commission Packet - May 28, 2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 9:28:31 AM
Creation date
5/24/2024 9:27:37 AM
Metadata
Fields
Template:
City Government
type
PCSR
date
5/28/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROTOTYPICAL BUILDING UTILITIES <br />THE FOLLOWING ARE STANDARD FOR PROTOTYPICAL LES SCHWAB TIRE CENTER BUILDINGS. UTILITIES MUST ALWAYS BE VERIFIED WITH EACH INDIVIDUAL SITE. <br />WATER <br />-FLUSH VALVES: <br />66.9 WSFU (OR 58 GPM) AT 60+ PSIG <br />-AVERAGE USE: <br />BUILDING:2500 GPD <br />LANDSCAPE:500 GPD <br />-PEAK DEMAND:58 GPM <br />-SERVICE SIZE: <br />-2" SERVICE LINE BETWEEN CONNECTION TO MAIN (TAP) AND METER <br />-1 1/2" WATER METER <br />-2" BACKFLOW PREVENTER (INTERNAL TO BUILDING) <br />-1" LANDSCAPE STUB WITH VALVE AND BACKFLOW PREVENTER <br />-FIRE SERVICE: <br />-TOTAL FIRE DEMAND:1,500 GPM (ESFR) 1,250 GPM @ MINIMUM 58 PSI AT <br />RISER, PLUS 250 GPM HOSE DEMAND. PROVIDE <br />MINIMUM 8" FIRE LEAD FROM POINT OF CONNECTION <br />TO RISER. <br />SANITARY SEWER <br />STORMWATER <br />-PHONE: <br />-CONDUIT:TWO (2) 4" <br />-POTS LINES:NINE (9) <br />-CABLE: <br />-CONDUIT:ONE (1) 2" OR ONE(1) 4" <br />-CABLE QUANTITY:ONE (1) COAXIAL CABLE <br />-POINT OF ENTRY:UNDER SLAB UP INTO 36"X36" TELEPHONE BACKBOARD CABINET <br />ELECTRICAL <br />-SECONDARY SERVICE: <br />-PREFERRED 3-PHASE, 208Y/120V, 600 AMPERES <br />-TYPICAL DEMAND:181 KW <br />-CONNECTED LOAD:183 KVA <br />-SERVICE CONDUCTORS:(2) SETS OF 4-350 KCMIL COPPER IN 3" CONDUITS <br />OR (2) SETS OF 4-500 KCMIL ALUMINUM IN 3 1/2" CONDUITS <br />-SITE SPECIFIC: IF FIRE PUMP REQUIRED, 3-PHASE, 480Y/277V SERVICE (SERVICE SIZE <br />DEPENDANT ON FIRE PUMP SIZE) <br />PHONE/CABLE <br />FREE STANDING SIGN <br />-AS ALLOWED BY CODE. LES SCHWAB PREFERS ONE MONUMENT SIGN AND ONE PYLON <br />SIGN. <br />EXTERIOR WALL SIGNS <br />TYPICAL SINGAGE INCLUDES FOUR (4) EXTERIOR WALL SIGNS WITH A TOTAL SIGN AREA <br />OF 190.31 SF <br />-FRONT ELEVATION:"ALIGNMENT-BRAKES-SHOCKS" 50.00 SF <br />-REAR/SHOWROOM ELEVATION:"LES SCHWAB LOGO" 46.77 SF <br />-SHOWROOM ELEVATION:"LES SCHWAB LOGO" 46.77 SF <br />-LOADING ELEVATION:"LES SCHWAB LOGO" 46.77 SF <br />-ALL DOWNSPOUTS COLLECTED UNDERGROUND (NO SPLASH PADS) UNLESS NOT <br />ALLOWED BY AUTHORITY HAVING JURISDICTION OR IF STORM DRAIN IS NOT <br />AVAILABLE AT SITE. <br />-TOTAL WASTE:43.5 FU <br />DOMESTIC:25 FU <br />SHOP SPACE:18.5 FU <br />-AVERAGE USE:2400 GPD <br />-PEAK EFFLUENT DISCHARGE:21.75 GPM <br />-SERVICE SIZE: <br />-SANITARY SERVICE: <br />PROPERTY STUB:6" AT 1% MINIMUM GRADE <br />DOMESTIC:4" AT 2% MINIMUM GRADE <br />SHOP SPACE:4" AT 2% MINIMUM GRADE <br />-SAND OIL INTERCEPTOR FOR SHOP SPACE: <br />MINIMUM:500 GAL (VERIFY W/ AUTHORITY HAVING JURISDICTION) <br />-SERVICE SIZE AFTER METER:2.5" (7" WATER GAUGE DISTRIBUTION PRESSURE) <br />ON BUILDING SIDE OF METER <br />-2 LBS IN AREAS WHERE POUNDS MEDIUM IS USED <br />-925 TOTAL MBH, 190' TO 285' DEVELOPED AT 7" WC <br />-TRANE HVAC UNITS:265 MBH (VARIES BY LOCATION) <br />-GAS FIRED UNIT HEATER:105 0R 45 MBH EACH (VARIES BY LOCATION) <br />-GAS FIRED RADIANT HEATERS: <br />-THREE (3) AT 75 MBH EACH (FOR 6 BAY LINEAR BUILDING LAYOUT) <br />-FOUR (4) AT 75 MBH EACH (FOR ALL OTHER BUILDING LAYOUTS) <br />GAS <br />'(6,*1&5,7(5,$352726(74_/(66&+:$%7,5(&(17(5 &,7<67$7( <br />_$//5,*+765(6(59('60%$<5+/,1($535(&$676725( 352727<3(4 <br />Page 66 of 71
The URL can be used to link to this page
Your browser does not support the video tag.