My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
JOINT FINANCE COMMITEE PACKET 04-30-2024
ElkRiver
>
City Government
>
Boards and Commissions
>
Joint Finance Committee
>
Packets
>
2024
>
04-30-2024
>
JOINT FINANCE COMMITEE PACKET 04-30-2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2024 11:54:46 AM
Creation date
4/29/2024 11:51:38 AM
Metadata
Fields
Template:
City Government
type
EDSR
date
4/30/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12345678910CA.2BEFGHJA7.2A.78.45.3A3004A3001A3003A3002DUSTCOLLECTORANNIE7x13990 DOOR LINE10x48WRAPPER8x46EXISTING 990 LINE994X LINE994X DOOR LINE18x53WRAPPER8x46MAGNUMTIMESAVERMAINT.206COMP.209UTILITY208A2011A2031A202110 BRICK14' CIADROUTERTABLE SAWSHAPER7x11SAW BENCH3 ASSEMBLY TABLES18x32SLAB STORAGE7'/8' CLAD8x50EXTERIOR DOOR LINE12x57HINGE STORAGE8x16SAW BENCHJB HDS 3x16GLASS 4x16GLASS 4x16EFX20x26STITCHER STOP17x27SPECIAL JBS11x13SPECIAL (?) SAWTABLE SAW9x10JB HDS 3x16ASSEMBLY TABLES12x17-8MAGNUMROUTER 3x14SIDE JBS8x26STITCHER & STOP25x14-6PARTS 3x14DOUBLE DOORS14x38WINDOW BOX INT TRIM56x65GLASS PROGRAM30x40WINDOW EXT JBSMUAA20416,213 SFDISTRIBUTION20234,427 SFPRODUCTION20039,669 SFWAREHOUSE2013,894 SFRECEIVING20414,553 SFFINISHING2031A310____________________________________________________________________________________________________________________________1A310____________________________________________________________________________________________________________________________2A310____________________________________________________________________________________________________________________________2A310____________________________________________________________________________________________________________________________DSPRAY207DRY RACK AREAPREPTABLEPREPTABLESKIRT BOARD(18' X 8')SKIRT BOARD(18' X 8')4x104x104x104x104x104x104x104x104x10 4x10 4x10 4x104x104x104x104x104x104x104x104x104x104x104x104x104x10 4x10 4x10 4x104x104x104x104x104x104x104x104x104x104x104x104x10CANTILEVERRACK9x16CANTILEVERRACK9x164x10 4x10 4x104x104x104x103x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-6CONVEYOR20x26CL9' - 3"C.R.C.R.C.R.8 x 100 WRAPPER4x104x104x103.5x7.5 3.5x7.5 3.5x7.5 3.5x7.5PLANER6x64x84x84x84x84x84x8 4x810' - 0"4x8SAW BENCH2 ASSEMBLY TABLES12x394x104x104x104x104x104x104x84x84x8 4x8 4x84x84x84x8 4x8 4x86' - 0"4' - 7"10' - 0"9' - 2"4x84x84x8 4x8 4x84' - 0"SIDE JBS8x2610' - 0"ASSEMBLY TABLES12x17-8JBS 4x9 JBS 4x9JBS 3x193-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-6 3-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-63-6x7-64x104x10 4x104x10 4x104x10 4x104x10 4x104x10 4x104x10 4x104x10 4x104x104x104x104x104x104x104x104x104x104x104x104x104x104x104x104x104x104x84x84x104x10 4x104x10 4x104x104x104x104x84x84x8CANTILEVERRACK9x16CANTILEVERRACK9x16CANTILEVERRACK9x16CANTILEVERRACK9x12CANTILEVERRACK9x124x10 4x10 4x104x104x104x104x10 4x104x104x104x810' - 9"11' - 8"11' - 8"10' - 9"11' - 8"11' - 8"3x7-63x7-63x7-63x7-611' - 0"3x7-63x7-610' - 0"10' - 0"9' - 1"4x7-6 4x7-6 4x7-6 4x7-6 4x7-6 4x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-63x7-616' - 4"16' - 4"2'-6" 9'-0" 5'-0" 9'-0" 5'-0" 9'-0" 5'-0" 5'-6"3'-6"5'-0" 9'-0" 5'-0" 9'-0" 7'-10"3'-4" 7'-4" 6" 9'-0" 5'-0" 9'-0" 5'-0" 9'-0" 5'-0" 7'-6"1'-6"5'-0" 9'-0" 5'-0" 9'-0" 5'-0" 9'-0"6'-6" 14'-4" 3'-4"3'-4" 26'-4" 2'-8"8" 49'-4" 50'-0" 23'-0" 3'-3 9/16"3'-4" 20'-4 7/16"6"9'-0" 5'-0" 9'-0" 26'-6"221'-0"152'-0"77'-0"450'-0"8'-0" 24'-0" 12'-0" 36'-0" 34'-0" 4'-0" 12'-0" 50'-0" 50'-0" 12'-0" 4'-0" 34'-0" 36'-0" 36'-0"352'-0"8'-0" 72'-0"200'-0"72'-0"37'-0" 4'-0"144'-8 3/4"124'-3 1/4" 44'-0"137'-0"450'-0"10'-8"GENERAL PROJECT NOTES1. OWNER FURNISHED EQUIPMENT SUPPLIERS ARE TO COORDINATE FINAL LOCATION OF EQUIPMENT AND INSTALLATION WITH THE OWNER.2. ELECTRICAL CONTRACTOR & CABLE CONTRACTOR ARE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED TO WALLS, FINISHES, CEILINGS ETC. IN THE COURSE OF THEIR CONSTRUCTION. IF CONTRACTORS BEGIN WORK IN AN AREA WITH EXISTING DAMAGE THEY ARE TO IMMEDIATELY NOTIFY THE OWNER OR ASSUME RESPONSIBILITY OF SUCH DAMAGE.NDATE:DRAWN BY:CHECKED BY:PROJECT NUMBER:COMPUTER DIRECTORY:1000 Twelve Oaks Center DriveSuite 200, Wayzata, MN 55391T: 952-426-7400F: 952-426-7440MohagenHansen.comTHE ARCHITECT SHALL BE DEEMED THE AUTHORS ANDOWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICE AND SHALL RETAIN ALL COMMON LAW,STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS OF THE ATTACHED DOCUMENTS.C:\Revit Projects\21250_HeritageMillwork_Master_nmissling@mohagenhansen.com.rvtCheckerAuthor03/25/202421250K:\Jobs\HeritageMillwork_21250\04_DwgHERITAGE MILLWORK16767 GATEWAY ROADELK RIVER, MN 55330FLOOR PLAN -OVERALLA2001/16" = 1'-0"A2001FLOOR PLAN OVERALLNOT FOR CONSTRUCTIONNO. DESCRIPTION DATE
The URL can be used to link to this page
Your browser does not support the video tag.