Laserfiche WebLink
waters work 12errnit has been obtained from the Department of Natural Resources unless a <br />sigiiificant area above the ordinary high-water level is also to be disturbed. The continuation of <br />existing uses, when the associated activities do not encroach further on the regulator floodplain <br />or truer associated standards in this ordinance. do not require a permit. <br />(c) Minimum DetK&4ment Standards <br />(1) All develo rnent must: <br />a. Be designed for modified) and adequately anchored to prevent flotation, collapse, or <br />lateral movement resulting from hydrodynamic and hydrostatic loads, including the <br />effects of buoyancy ; <br />b. Be constructed with materials and equipment resistant to flood damage; <br />a Be constructed by methods and Practices that minimize flood damage; <br />d. Be reasonably safe from flooding and consistent with the need to minimize flood <br />da_ mage; <br />e. Be assured to provide adequate drainage to reduce exposure to flood hazards; <br />f. Not be detrimental to uses in adjgjnjDg areas: and <br />g. Not adversely affect the efficiency or restrict the flood carrying capacin• of the <br />channel and adjoining floodplain of any tributan, watercourse or drainage system. <br />(2) Buildings and Structures. No new structures, such as buildings or accessory structures may be <br />permitted in the regulator floodplain. Modifications and alterations of nonconforming <br />structures is subject to the standards in Sec. 30-1916. <br />(3) Subdivisions. All new lots must be able to accommodate for a building site with a natural grade <br />outside of the floodplain. All subdivisions must have vehicular access both to the <br />subdivision and to the individual building sites no lower than two feet below the Regulatory <br />Flood Protection Elevation (RFPE).. <br />(4) EncroachmentAnal ,sis. Development in the following areas requires hydrologic and hydraulic <br />analysis performed by a professional engineer, or using other standard engineering practices <br />4e.g.. projects that restore the site to the previous cross -sectional area) <br />a. In a floodway. development may not result in any of the following; during the one - <br />percent annual chance flood: cause a stage increase of 0.00 feet or greater, obstruct <br />flood flows, or increase velocities. <br />b. In areas where a floodway has not been delineated, development may not allow stage <br />increases more than one-half (0.5) foot at any point during the one -percent chance <br />flood. This evaluation must include the cumulative effects of previous <br />encroachments. A lesser water surface elevation increase than one-half (0.5) foot is <br />required if, due to the water surface level increase, increased flood damages would <br />potentially result. <br />(S) Fences not meeting the definition of farm fences are not permitted. <br />(6) TmL.Oortafion Facilities. Railroad tracks roads and bridges must be elevated to the Rggulaj= <br />Flood Protection Elevation (RI;PE) where such facilities are essential to the orderly, <br />functioning of the area, or where failure or interruption would result in danger to public <br />