Laserfiche WebLink
EXIIIBIT B <br />(Technical Standards- Live Origination Sites) <br />With respect to all sites listed in Exhibit A, the System shall meet or exceed the following <br />requirements: <br />1. The System shall operate in conformance with the technical standards <br />promulgated by the FCC pursuant to Title 47, Section 76.601 to 76.617, as may be <br />amended or modified from time to time. <br />2. The System shall be capable of continuous 24-hour operation without <br />signal degradation. <br />3. The System shall be capable of operation without failure, material performance <br />changes or signal degradation over an outdoor temperature range of -40 degrees F to +130 <br />degrees F and over a variation in supply voltages from 105 to 130 volts AC. <br />4. The System will provide access channel connections up to the demarcation <br />point, both upstream and downstream, without material signal degradation or deterioration and <br />with signal quality equal to or better than any other channels. Material signal degradation or <br />deterioration where any signal problem including ghosting or other audio or visual distortion or <br />interference is apparent without special testing. The Grantee shall not be responsible for <br />technical problems deriving from facilities or equipment located beyond the demarcation point, <br />within the institutional site. <br />iCSOPEN\SH255\ 16\843960.v2-2/3/23 <br />