� <br />1.0' MAX <br />� <br />1.0' MAX <br />� <br />5.0' MAX <br />� <br />GRADE LEVELIN GROUND <br />TRACER WIRE ACCESS BOX <br />AND DRIVE-IN MAGNESIUM � <br />GROUNDING ANODE (SEE <br />� WATERMAIN DETAIL 3408) <br />12 AWG COPPER <br />CLADSTEEL BLUE (TYP) <br />� MAINLINE TO LATERAL <br />LUG CONNECTOR <br />� SERVICE SADDLE ` WATER SERVICE <br />RIGHT-OF-WAY m <br />� LINE <br />N <br />� <br />� <br />�DRIVE IN MAGNESIUM <br />GROUNDING ANODE ROD <br />CURBSTOP BOX � <br />NOTES: <br />TAPE OR PLASTIC WIRES SHOWN AWAY FROM PIPE FOR <br />CLARITY. WIRE SHALL BE INSTALLED <br />TIE (TYP) IMMEDIATELY ADJACENT TO THE SERVICE <br />PIPE.THE WIRES SHALL BE FASTENED TO <br />THE PIPE WITH A TAPE OR PLASTIC TIES <br />WATER SERVICE PLANVIEW AT 5' INTERVALS. <br />I I 1.5' MAX � FINISHED GRADE <br />~I I~ <br />GRADE LEVELIN GROUND <br />TRACER WIRE ACCESS BOX <br />AND DRIVE-IN MAGNESIUM <br />GROUNDING ANODE (SEE <br />DETAIL 3408) <br />COIL 2' OF EXTRA RED AND BLUE <br />WIRE IN AN ACCESS BOX. RED WIRE <br />IS FROM GROUNDING AND BLUE WIRE <br />IS TRACER WIRE ON SERVICE PIPE <br />THAT CONNECTS TO THE MAIN <br />LINEWIRE. <br />12 AWG COPPER <br />CLADSTEEL RED <br />FACTORY CONNECTED TO <br />GROUND ROD <br />DRIVE IN MAGNESIUM � <br />GROUNDING ANODE ROD <br />� CURBSTOP BOX <br />12 AWG COPPER <br />CLADSTEEL BLUE (TYP) <br />DO NOT SECURE WIRES TO CURB STOP BOX AS <br />TO TO ALLOW FOR ADJUSTMENTS WITHOUT <br />DAMAGING WIRE <br />CURBSTOP <br />WIRE CONTINUES WITH WATER <br />SERVICE AND CONNECTS TO MAIN LINE <br />WIRE SEE PLAN VIEW ABOVE) <br />WATER SERVICE SECTION VIEW <br />REV: 2/2017 <br />cP� <br />TRACER WIRE DETAIL <br />STANDARD <br />PLATE <br />N0. <br />I •' <br />• <br />