Laserfiche WebLink
CASTING <br />CHIMNEY SEAL AROUND RINGS <br />4"-12" CRETEX PRO—RING RT 36-24 <br />4 ,� <br />� <br />� <br />� <br />x <br />Q <br />� <br />0 <br />I <br />� <br />G�a <br />v <br />5" 24" X 36" <br />° � � � . <br />.a <br />2�� <br />a <br />� I <br />I <br />WALLS TO BE CONSTRUCTED OF <br />PRECAST SECTIONS OR CONCRETE <br />SEWER BLOCK. BLOCK SHALL BE <br />PLASTERED ON INTERIOR AND <br />EXTERIOR. <br />3" <br />6" CONCRETE BASE POURED IN PLACE OR <br />4" MINIMUM PRECAST BASE. <br />NOTE: <br />REINFORCING SHALL CONSIST OF A SINGLE LINE <br />OF STEEL WIRE FABRIC HAVING AN AREA OF <br />NOT LESS THAN 0.17 SQ. IN. PER FOOT OF HEIGHT. <br />c� <br />� <br />a� , � :� �: � � � : <br />..a a a � a <br />. � . . . ' d • <br />SHALLOW CATCH BASIN <br />REV: 2/2023 <br />STANDARD <br />PLATE <br />N0. <br />2500 <br />