Laserfiche WebLink
7) 750 gal Dose tank (code minimum) 1000 gal Dose tank (design size / LUG req'd) at 23.14 gpi <br />leads to a: <br />8.3 inch swing on Demand float, <br />12 inches from bottom of tank to "pump OFF"' float <br />20 inches from bottom of tank to "pump ON" float <br />23 inches from bottom of tank to "Hi Level" float <br />(optional Time dosing of: <br />(this delivers Average flow, =70% of Peak design flow) <br />4.5 min ON <br />8.5 hrs OFF <br />12 inches to "timer ON" float <br />468 gallons reserve capacity (after HLA activation -demand dosed) 33 inches to "Hi Level" float <br />72 inches, or b.00 ft. to Redox or other limiting condition (This must match the soil boring log) <br />Treatment zone contains EKI inches of 0% soil credit, and inches of 50% soil credit <br />36 inches, or 3.00 ft. of vertical separation required <br />leads to bottom of rock no more than: <br />3b inches, or 3.0 ft. Below existing grade CRITICAL FOR FUTURE CERTIFICATIONSIH <br />6 inches of rock below the pipe <br />2 inches of rock to cover the pipe <br />Overall Dimensions: 19.0 ft. wide by 52.b ft. long Pressure Bed <br />Rock Bed materials: <br />19 ft. by 52.b ft. by inches total, plus 20% gives 30 yd3 or *1.4= 42 ton <br />I hereby certify that I have completed this work in accordance with all applicable ordinances, rules and laws. <br />William Stone <br />Designer Signature <br />Rotz Septic Et Excavating Inc. <br />Company <br />3987 5/18/2022 <br />License# Date <br />