Laserfiche WebLink
INSPECTOR CHECKLIST -Pressure bed <br />17801 Joplin Street NW <br />WELL setbacks: 20' -50' to sewer tine req's MDH pressure test form (5 psi for 15 min) <br />50' to everything 100' to drainfield with shallow well <br />PROPERTY LINES setback: 10' to everything <br />Road setback: platted: 10' prop line. Metes Et bounds: out of road easement, or outer ditch. <br />LAKE / BLUFF setback: 20' for bluff. Lakes: GD _, RD _, NE Protected wetland _ <br />Building setbacks: 10' for everything, 20' for dispersal area. <br />WATER LINE under pressure 10' to bed,tank Et sewer line. (else sewer line > 12" below) <br />Sewer line Et tank connection (no hard 90's, long sweep 90 or 2-45's, minimum slope 1" in 8' = 1%) <br />(no depth req's, clean out every 100', Sch 40 pipe) <br />ElSeptic tank and risers (water tight risers, baffles, insulated, proper depth, existing verified by pumping) <br />mfg 1500 gallons multiple tanks or compartments req'd <br />ElRiser over outlet, riser over inlet or center, and 6"+ inspection pipe over any remaining baffles. <br />No effluent fitter Et alarm <br />Dose tank, risers and piping (water tight risers, insulated, proper depth, drainback) <br />mfg 1000 gallons <br />Optional Time dosing of: <br />dose pump 43 gpm 15 head VERIFY PUMP CURVE 4.5 min ON 8.5 hr OFF <br />verify that installed "vertical lift from pump to laterals" is no more than design value of 8 feet <br />float setting drop 8.3 inches at 23.14 gpi "DESIGNED" 5.2 inches approx float tether length <br />193.0 gal dose divided by gpi "INSTALLED" = inches float drop (field corrected <br />LABEL pump requirements and drawdown on riser or panel <br />ElCam lock reachable from grade - 30" max. J-hook weep hole. Supply tine access (no hard 90's) <br />2.0 inch supply pipe: Sch40, sloped 1 /8"+, supported by 4" sch40 sleeve or compacted, and buried 6"+. <br />splice box / control panel / electrical connections / Hi Level Alarm <br />flow measurement: CT, ETM, time dosed, home water meter <br />El Bed dimensions 19 X 52.6 <br />1-1 Rock depth below pipe 6 inches <br />ElRock bottom elevation 36.0 inches from Grade to bottom of rock (max) <br />cover depth of 12"+ VERIFY <br />6 laterals (1-2' from edge of rock) <br />2.00 inch pipe size (Sch40 pipe Et fittings) <br />3.0 ft lateral spacing <br />3/16 inch perforations <br />3.0 ft perforation spacing <br />Air inlet at end of laterals, and at top feed manifold if necessary. VERIFY <br />clean outs (deep bed T of head) (no hard 90's) <br />4" inspection pipe to bottom of rock, anchored VERIFY <br />Abandon existing system <br />monitoring plan and type <br />well abandonment form - <br />if necessary NO Re -use existing tank certification <br />if necessary <br />