Laserfiche WebLink
City of Elk River -HRA – Main and Gates Redevelopment; Elk River, Minnesota <br />AET Proposal No. P-0001445 <br />April 12, 2021 <br />Page 2 of 4 <br /> <br />American Engineering Testing, Inc. <br /> <br />We assume that the Client will backfill and repair any boreholes that may slough after our exploration is <br />complete. AET cannot accept any liability associated with pedestrian injury after we leave the site. <br /> <br />Based on our knowledge of the site we plan to drill the borings with a truck mounted drill vehicle. Accessing <br />the boring locations may leave ruts in the ground. We assume that the Client will perform any site restoration <br />work. We have not included a fee for site restoration in our cost estimate. <br /> <br />Underground Utilities <br />Before we drill, we will contact Gopher State One Call to locate public underground utilities. Gopher <br />State One Call does not currently charge for this service, but they will not locate private underground <br />utilities or structures. Examples of private utilities include, but are not limited to, propane lines, sewer <br />laterals, sprinkler systems, site lighting, and electric and data lines between buildings. Gopher State One <br />Call indicates that the property owner is responsible for locating all private underground utilities <br />and structures. We request that you please coordinate this activity with the owner and AET prior to AET <br />beginning any subsurface exploration. Also, please provide us with any maps, plans and records showing <br />the location of all private utilities and structures. <br /> <br />We can provide you with names and contact information for private utility locators. These companies <br />usually charge a fee for their services. Also, please note that private locators cannot guarantee that all <br />private utilities will be located. For the private locator to be accurate and effective, the property owner <br />must provide maps, plans and records showing the location of all private utilities and structures. The <br />property owner must also provide a knowledgeable site representative to meet with the private locator and <br />AET personnel. <br /> <br />AET shall be entitled to rely upon the accuracy of all location information supplied by any source. We <br />will not be responsible for any damages to underground utilities or structures not located or incorrectly <br />identified by the property owner, any maps, plans or records, or public or private utility locator providers. <br /> <br />Laboratory Testing <br />We will initiate routine laboratory testing by reviewing each recovered soil sample to assess the major <br />and minor soil components, while also noting the color, degree of saturation, and lenses or seams in the <br />samples. If we encounter cohesive soil, we will test selected samples for moisture content. <br /> <br />On completion of testing, we will visually/manually classify each sample on the basis of texture and <br />plasticity in accordance with the Unified Soil Classification System and prepare the boring logs. <br /> <br />Report <br />Following the field and laboratory services, the logs of the test borings, the laboratory test results will be <br />provided. <br /> <br />Fees: <br />For the scope of services described above, our charges will be as follows: <br /> <br />1. Utility Clearance & Boring Layout $ 300.00 <br />2. Drilling and Sampling – 2 borings; 30 feet $ 1,900.00 <br />3. Laboratory testing, classification, and boring logs $ 400.00 <br />4. Report $ 400.00 <br /> TOTAL ESTIMATE $ 3,000.00