My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4.4 SR 04-19-2021
ElkRiver
>
City Government
>
City Council
>
Council Agenda Packets
>
2021 - 2030
>
2021
>
04-19-2021
>
4.4 SR 04-19-2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2021 10:38:38 AM
Creation date
4/16/2021 8:54:15 AM
Metadata
Fields
Template:
City Government
type
SR
date
4/19/2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Elk River Design Standards <br />Materials <br />Pipe and fittings for non -pressure gravity sewers and services shall conform to the requirements <br />of ASTM D 1784 and D 3034, or ASTM F 789 and D 3034, and have push -on joints with <br />elastometric gaskets, as follows: <br />A. SDR 35 for depths up to 18-ft. <br />B. SDR 26 for depths 18-ft to 30-ft. <br />C. Ductile Iron Pipe, as specified below, for depths greater than 30-ft. <br />2. Pipe and fittings for pressure forcemains shall conform to the requirements of ASTM D 1784 <br />and the following supplementary provisions: <br />A. For pipes 12" in diameter and smaller, the pipe, fittings and accessories shall be <br />C900 and have a minimum dimension ratio (DR) of 18 corresponding to a working <br />pressure of 150 psi. For pipes 14" in diameter and larger, the pipe, fittings and <br />accessories shall be C905 and have a minimum dimension ratio (DR) of 25 <br />corresponding to a working pressure of 165 psi. <br />B. Joints shall be push -on type with elastometric gaskets. <br />C. Forcemain pipe shall have location tracer wire placed with it. Location wire shall be 8- <br />gauge plastic jacket type TW or THW. Splices shall be made using 3M cast kits and shall <br />not occur more frequently than one per 250 feet of pipe. <br />All ductile iron pipe shall conform to the requirements of AWWA C 151 (ANSI A21.51) and as <br />follows: <br />A. CL 52 for depths 30-ft to 60-ft. <br />B. CL 54 for depths greater than 60-ft. <br />4. For service pipe placed at a depth of 30 feet or greater, the pipe material shall match the mainline <br />pipe as called for in item B3 above. Service pipe placed shallower than 30 feet of depth shall be <br />SDR 26. <br />Lift Station <br />1. Site <br />A. Drainage: the top slab of the wet well and valve vault should be set high enough to allow <br />drainage away from the lift station structure. <br />B. Access: an access driveway that is 12' wide x 20' long shall be provided for the lift <br />station. <br />C. A hydrant should be located within 50 feet of the lift station. <br />D. A streetlight should be installed at each lift station. <br />2. General Configuration — the plan must indicate the proposed location of the Control Panel <br />which is subject to approval by the Wastewater Superintendent and City Engineer. <br />3. Structures <br />A. Minimum Size — 72" is to be a minimum diameter for both the wet well and valve vault. <br />Depending on the size of the pumps, the wet well may need to be larger. <br />B. The bottom of the valve vault is to be provided with 4" of slope across the vault to the <br />drain outlet. The drain line should exit the valve vault horizontally through the wall <br />instead of vertically through the floor. A backflow check valve needs to be installed on <br />the drain line to prevent backflow of water and gas from the wet well to the valve vault. <br />A trap should also be located in the drain line as a back up to the check valve for <br />preventing gas flow back into the vault. <br />C. All pipe work and fittings shall be contained within the valve manhole. Short -radius 90- <br />© City of Elk River, Minnesota —All rights reserved 20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.