Laserfiche WebLink
City of Elk River Design Standards <br />Section 3400 - Watermain Design Standards <br />Design Criteria <br />1. All Watermain design shall comply with the latest edition of the Ten States Standards for Water <br />Works, APWA and Minnesota Department of Health standards. <br />2. Water System installation and testing shall be in accordance with CEAM standard specifications <br />except as modified herein. <br />3. The minimum size of watermain shall be 8 inches. (Hydrant leads can be 6") <br />4. Watermain pipe shall be ductile iron in accordance with AWWA C151. <br />5. The minimum bury depth of watermain shall be 7'- 6" to top of pipe. <br />6. The minimum size of water service lines and corporations shall be 1 inch. When water service <br />lines exceed 200-feet, the service line and corporation shall be 11/2". <br />7. No dead-end mains shall be constructed. All watermains shall be looped. <br />8. Water looping outside of the Right of Way shall be HDPE, valved at each end with no <br />connection/services in between. <br />9. Temporary dead-end mains shall be equipped with a fire hydrant for flushing purposes. <br />10. Hydrants shall be spaced so that all portions of a building or residence to be protected are within <br />a 250-foot radius of a hydrant. (Final review will be made by the Fire Chief and City Engineer) <br />11. Each hydrant lead shall be equipped with a resilient seated valve for shut-off purposes and <br />installed in accordance with the standard detail. <br />12. Valves shall be placed throughout the distribution system so that each portion may be isolated <br />with the least interruption of service. Valves shall be placed at each roadway intersection or the <br />intersection of watermains. (Final review will be made by the Water Superintendent and City <br />Engineer) <br />13. A "Hydrafinder" locating device shall be installed on each hydrant installed and shall be mounted <br />on the upper flange of the hydrant with a straight mounting bracket as indicated in Elk River <br />Standard Plate 3401. For every five hydrant locating devices installed, one extra hydrant locating <br />device shall be delivered to the Elk River Municipal Utilities. <br />14. All hydrants and leads shall be restrained from the main to the hydrant using threaded rods or <br />Megalug restraint glands in accordance with the standard detail plates. <br />15. To allow the hydrant to drain after use, the hydrant bottom shall be surrounded by Coarse Filter <br />Aggregate (Mn/DOT 3149.2H) or 3/4" - 11/2" clear drain rock covered with plastic material as <br />indicated on Standard Plate 3402. <br />16. All watermain valves shall be operated only by Elk River Municipal Utility forces (763.635.1361). <br />© City of Elk River, Minnesota — All rights reserved 7 <br />