Laserfiche WebLink
1. DO NOT SCALE DRAWINGS FOR BUILDING <br />PURPOSES. USE PLAN INFORMATION, <br />DIMENSIONS, DETAILS, SHOP DRAWINGS <br />AND FIELD VERIFICATION. <br />2. GENERAL CONTRACTOR SHALL VERIFY ALL <br />DIMENSIONS AND CONDITIONS OF THE SITE <br />AND EXISTING BUILDING, AND REPORT ANY <br />DISCREPANCIES TO THE ARCHITECT <br />BEFORE COMMENCING WITH ANY WORK. <br />3. GENERAL CONTRACTOR AND ALL <br />SUBCONTRACTORS SHALL BECOME <br />FAMILIAR WITH THE SITE AND EXISTING <br />CONDITIONS DURING THE BID PERIOD. <br />SUBMITTING A BID FOR THE WORK <br />CONSTITUTES AN UNDERSTANDING BY THE <br />CONTRACTOR/SUBCONTRACTOR OF THESE <br />CONDITIONS. <br />4. PAINT ALL INTERIOR EXPOSED STEEL, TYP. <br />5. PAINT ALL EXTERIOR EXPOSED STEEL WITH <br />EPOXY PAINT, TYP. <br />6. ALL EXPOSED WELDS SHALL BE <br />CONTINUOUS, GRIND SMOOTH. <br />7. CONTRACTOR TO PROVIDE REQUIRED BASE <br />MATERIALS UNDER SITE FINISHES -SEE <br />SPECIFICATIONS. <br />8. BELOW ALL INTERIOR SLABS ON GRADE: <br />PROVIDE 6" COMPACTED SAND OVER POLY <br />VAPOR BARRIER OVER COMPACTED BASE. <br />General Notes <br />FIRST FLOOR <br />100' -0" <br />EXIST. LEVEL 2 <br />111' -6" <br />T.O. PARAPET <br />WALL <br />128' -0" <br />AREA A LEVEL 2 <br />114' -0" <br />D1 <br />A3.10 <br />29327 SF <br />VEHICLE STORAGE <br />114 <br />1745 SF <br />LUNCHROOM <br />1035960 SF <br />INVENTORY <br />119 <br />1171 SF <br />CUBICALS <br />8' x 8' <br />207 151 SF <br />OFF. <br />216 <br />CLEAR12' - 10"ABCDEFG <br />2 " / 1 '-0 " <br />3" / 1'-0"CLEAR8' - 3"CLEAR19' - 7 1/4"FIRST FLOOR <br />100' -0" <br />EXIST. LEVEL 2 <br />111' -6" <br />T.O. PARAPET <br />WALL <br />128' -0" <br />AREA A LEVEL 2 <br />114' -0" <br />C1 <br />A3.10 <br />827 SF <br />TECH SERVICES <br />WORKSHOP <br />118 <br />842 SF <br />WATER SERVICES <br />WORKSHOP <br />117853 SF <br />LINEMEN <br />WORKSHOP <br />116 <br />1505 SF <br />TRAINING <br />220 <br />1745 SF <br />LUNCHROOM <br />103 <br />1033 SF <br />HALL <br />102 <br />2345678910 <br />The above drawings, specifications and ideas, design and arrangements represented are and shall remain the property of the Architect, and no part shall be copied, disclosed to others, or used in connection with any other project for which they they have been prepared and developed without the written permission of the Architect. Visual contact with these drawings or specifications shall constitute conclusive evidence of these restrictions.I hereby certify that this plan, specification, or report was prepared by me or under my directsupervision, and that I am a duly Licensed Architect under the laws of the State of Minnesota.Architect: Michael Schellin, AIA© 2019 Kodet Architectural Group, Ltd.License Number: 43591DateDate:Drawn By:Project No.:Checked By:1 2 3 4 5 <br />D <br />C <br />B <br />A 6/28/2018NOT FOR CONSTUCTION KODET ARCHITECTURAL GROUP15 Groveland Terrace | Minneapolis, MN 55403-1154612.377.2737Kodet Architectural Group, Ltd.| www.kodet.com9/15/2020 2:36:21 PM9/15/2020 2:36:21 PM C:\Users\Office\Documents\108820_Elk River Municipal Utility Building_DD-1_Leintz Remote.rvt108820AuthorCheckerELK RIVER MUNICIPAL UTILITIESA3.10 <br />Building <br />Sections 1705 Main Street, Elk River, MN 55330Elk River Municipal Utilities |Material Keying Legend <br />Graphic Scale <br />Key Plan <br />1/8" = 1' -0" <br />0'4'8'16' <br />1/8" = 1'-0"A3.10 <br />C1 E/W SECTION AT INVENT., VEHICLE, & OFFICE <br />1/8" = 1'-0"A3.10 <br />D1 N/S SECTION AT OFFICE Revisions