My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4.3.b. PCSR 09-22-2020
ElkRiver
>
City Government
>
Boards and Commissions
>
Planning Commission
>
Planning Packets
>
2011-2020
>
2020
>
09-22-2020
>
4.3.b. PCSR 09-22-2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2020 9:30:48 AM
Creation date
9/17/2020 9:25:02 AM
Metadata
Fields
Template:
City Government
type
PCSR
date
9/22/2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN <br />UP <br />General Notes <br />1. CONCRETE BLOCK DIMENSIONS ON <br />FLOOR PLANS ARE NOMINAL AND <br />TAKEN FROM FACE OF BLOCK. <br />2. AT EXISTING WALLS, DIMENSIONS ARE <br />TAKEN FROM FACE OF EXISTING WALL <br />SURFACE. <br />3. AT METAL STUD / GYPSUM BOARD <br />PARTITIONS, DIMENSIONS ARE TAKEN <br />FROM CENTERLINE OF STUD. <br />4. FOR PARTITION TYPES, SEE SHEET A8.4. <br />5. TRANSITIONS BETWEEN FLOOR <br />MATERIALS TO BE LOCATED AT <br />CENTERLINE OF DOOR BETWEEN <br />ROOMS U.N.O. <br />6. ALL PENETRATIONS THROUGH FIRE- <br />RATED WALLS ARE TO BE SEALED WITH <br />FIRE RETARDANT SEALANT. ALL OTHER <br />PENETRATIONS THROUGH OTHER <br />WALLS TO BE SEALED COMPLETELY <br />WITH SEALANT. <br />7. ALL CONDUIT IN EXPOSED CONCRETE <br />BLOCK PARTITION TO BE CONCEALED. <br />8. COORDINATE PLUMBING WITHIN <br />CONCRETE BLOCK, PRECAST, OR <br />GYPSUM BOARD PARTITIONS AND <br />FURRING. <br />9. AT EXPOSED PRECAST PARTITIONS, ALL <br />CONDUIT AND PIPING TO BE <br />CONCEALED OR RUN ON BACK SIDE IN <br />FURRING OR ABOVE CEILINGS. <br />10. CONTRACTOR SHALL PROVIDE (1) <br />ADDITIONAL SURROUNDS 1'-4" WIDE BY <br />1'-0" DEEP PER FLOOR FOR MISC. <br />PIPE/DUCT/COLUMN PENETRATIONS. <br />UTILIZE PARTITION TYPE F4F. <br />11. SLOPE TILE FLOORS IN RESTROOMS <br />WITH FLOOR DRAINS TO DRAIN AT <br />1/4"/FT. EXCEPT AT RESTROOMS IN <br />EXISTING BUILDING. <br />C1 <br />A3.10 <br />D1 <br />A3.10 <br />827 SF <br />TECH SERVICES <br />WORKSHOP <br />118 <br />842 SF <br />WATER SERVICES <br />WORKSHOP <br />117 <br />853 SF <br />LINEMEN <br />WORKSHOP <br />116 1745 SF <br />LUNCHROOM <br />103 <br />88 SF <br />EXIST. RR <br />107A <br />243 SF <br />MECH. <br />115 <br />ELEV. <br />1033 SF <br />HALL <br />102 <br />746 SF <br />MEN'S LOCKER <br />ROOM <br />107 <br />91 SF <br />VEST. <br />101 <br />PATIO <br />290 SF <br />STOR. <br />118A <br />290 SF <br />STOR. <br />117A <br />293 SF <br />STOR. <br />116A <br />RR <br />110 <br />RR <br />105A STAIR <br />106 <br />240 SF <br />WOMEN'S LOCKER <br />ROOM <br />105 <br />SHOWER <br />109 <br />SHOWER <br />108 <br />RR <br />111 <br />235 SF <br />ELECT. <br />104 <br />J.C. <br />112 <br />ICE <br />A <br />AA <br />243 SF <br />PATIO STORAGE <br />103A <br />WASHWASH DRY <br />140' - 0" 17' - 0" 44' - 7" <br />29' - 4" 28' - 0" 22' - 0" 20' - 8" <br />A4.3A1 <br />A2 <br />A4.3A3 <br />A4 <br />A4.3B3 <br />B4 <br />A4.3 <br />A5 <br />B5 <br />2 3 4 5 6 7 8 9 10 <br />A <br />B <br />C <br />D <br />The above drawings, specifications and ideas, design and arrangements represented are and shall remain the property of the Architect, and no part shall be copied, disclosed to others, or used in connection with any other project for which they they have been prepared and developed without the written permission of the Architect. Visual contact with these drawings or specifications shall constitute conclusive evidence of these restrictions.I hereby certify that this plan, specification, or report was prepared by me or under my directsupervision, and that I am a duly Licensed Architect under the laws of the State of Minnesota.Architect: Michael Schellin, AIA© 2019 Kodet Architectural Group, Ltd.License Number: 43591DateDate:Drawn By:Project No.:Checked By:1 2 3 4 5 <br />D <br />C <br />B <br />A 6/28/2018NOT FOR CONSTUCTION KODET ARCHITECTURAL GROUP15 Groveland Terrace | Minneapolis, MN 55403-1154612.377.2737Kodet Architectural Group, Ltd.| www.kodet.com9/15/2020 2:36:11 PM9/15/2020 2:36:11 PM C:\Users\Office\Documents\108820_Elk River Municipal Utility Building_DD-1_Leintz Remote.rvt108820AuthorCheckerELK RIVER MUNICIPAL UTILITIESA2.1 <br />Enlarged Plan1705 Main Street, Elk River, MN 55330Elk River Municipal Utilities |0'2'4'8'Revisions1/8" = 1'-0"A2.1 <br />1 FIRST FLOOR OFFICE/WORKSHOPS <br />TRUE PLAN <br />N <br />N
The URL can be used to link to this page
Your browser does not support the video tag.