Laserfiche WebLink
GENERAL PROJECT INFORMATION <br />PROJECT LOCATION AND NARRATIVE: <br />THIS PROJECT CONSISTS OF A 31 LOT SINGLE FAMILY SUBDIVISION IN ELK RIVER, MN THE 51TE Is LOCATED <br />NEAR LONGITUDE-935911, LATITUDE 45. 3255. THE SITE IS ACCESSED FROM YORK STREET NW AND 195TH <br />AVENUE NW <br />CONSTRUCTION ACTIVITIES INCLUDE GRADING, UTILITY INSTALLATION, AGGREGATE & BITUMINOUS PLACEMENT, <br />CURB AND GUTTED,, SIDEWALK AND BITUMINOUS TRAIL CONSTRUCTION, STORM SEWER INSTALLATION, <br />INFILTRATION BASIN CONSTRUCTION. AND HOMEBUDDING. <br />CONSTRUCTION IS PLANNED TO BEGIN SUMMER OF 2020 AND HOMEBUILDING IS ANTICIPATED TO EXTEND <br />INTO 2022. <br />RESPONSIBLE PARTIES <br />CONTRACTOR MUST BE TRAINED FOR BOTH CONSTRUCTION INSTALLER AND SITE MANAGEMENT PER <br />REOUIREMENTS OF THE PERMIT, PART IILF <br />BENZINGER PROPERTIES INC. JEFF BENZINGER 763-428-3039 <br />OWNER CONTACT PERSON PHONE <br />OTTO ASSOCIATES INC, CARA SCHWAHN OTTO 763-632-4727 <br />PLAN PREPARED CONTACT PERSON PHONE <br />TRAINING: 1112912018 (EXPIRES 2022) U OF MN CERTIFICATION - DESIGN OF CONSTRUCTION SWPPP <br />312912017 (EXPIRES 2020) U OF MN CERTIFICATION - SITE MANAGEMENT <br />CONTRACTOR (RESPONSIBLE FOR CONTACT PERSON PHONE <br />INSTALLATION & INSPECTION) <br />CITY OF ELK RIVER BRANDON WISNER 763-635-1054 <br />PARTY RESPONSIBLE FOR LONG TERM 0&M OF CONTACT PERSON PHONE <br />PERMANENT STORMWATER MANAGEMENT SYSTEM <br />PROJECT AREAS' <br />TOTAL PROJECT SIZE (DISTURBED AREA) = 15.0 ACRES <br />EXISTING AREA OF IMPERVIOUS SURFACE = 0.0 ACRES <br />POST -CONSTRUCTION AREA OF IMPERVIOUS SURFACE = 4, Z ACRES <br />TOTAL NEW IMPERVIOUS SURFACE AREA CREATED = 4, Z ACRES <br />RECEIVING WATERS <br />SURFACE WATERS AND WETLANDS THAT WILL RECEIVE STORM WATER RUNOFF FROM THE SITE AND ARE <br />WITHIN ONE (1) MILE OF THE SITE ARE INDICATED WITH DIRECTION ARROW ON THE SWPPP PLAN SHEET <br />AND ARE LISTED BELOW <br />NAME OF WATER BODY IMPAIRED WATER <br />UNNAMED WETLAND NO <br />THE OWNER SHALL SUBMIT A NOTICE OF TERMINATION (NOT) AFTER ONE OF THE FOLLOWING HAS BEEN <br />COMPLETED, WHICHEVER OCCURS FIRST <br />1. WITHIN 30 DAYS AFTER FINAL STABILIZATION (PERMIT SECTION XG IS COMPLETE, <br />Z WITHIN 30 DAYS AFTER SELLING OR OTHERWISE LEGALLY TRANSFERRING THE ENTIRE SITE. <br />3 IF 907 (BY AREA) OF ALL ORIGINALLY PROPOSED CONSTRUCTION ACTIVITY HAS BEEN COMPLETED AND <br />PERMANENT COVER HAS BEEN ESTABLISHED ON THOSE AREAS <br />ALTERNATIVELY, THE OWNER MAY SUBMIT A PERMIT MODIFICATION FORM FOR EACH <br />HOMESUDDER/HOMEOWNER AS LOTS ARE SOLD. THE NEW OWNER/CONTRACTOR SHALL BE RESPONSIBLE <br />FOR AMENDING THE SWPPP AS NECESSARY TO SPECIFICALLY ADDRESS THEIR WORK AND SUBMIT A NOTICE <br />OF TERMINATION (NOT) ACCORDING TO THE SAME REQUIREMENTS ABOVE, <br />CONSTRUCTION ACTIVITY NOTES <br />ALL CONSTRUCTION ACTIVITIES MUST MEET THE REQUIREMENTS OF THE MPCA S NPDES GENERAL <br />STORMWATER PERMIT FOR CONSTRUCTION ACTIVITY. <br />EROSION PREVENTION' <br />ALL EXPOSED SOIL AREAS RADA STOCKPILES) MUST BE STABILIZED, STABILIZATION MUST BE <br />INITIATED IMMEDIATELY TO LIMIT SOIL EROSION BUT COMPLETED NO CASE LATER THAN 14 DAYS <br />AFTER THE CONSTRUCTION ACTIVITY IN THAT PORTION OF THE SITE HAS TEMPORARILY OR <br />PERMANENTLY CEASED. <br />TEMPORARY TURF RESTORATION SHALL BE MNDOT SEED MIX 25-121 ® 61 LB/ACRE WITH <br />MNDOT TYPE I MULCH ® 2 TONS/ACRE (DISC ANCHORED) AND 12-5-70 TYPE 3 FERTILIZER <br />(350 LBS/ACRE). STABILIZATION MUST BE INITIATED IMMEDIATELY BUT IN NO CASE COMPLETED <br />LATER THAN 14 DAYS AFTER THE ACTIVITY IN THAT PORTION OF THE SITE HAS TEMPORARILY <br />OR PERMANENTLY CEASED. <br />PERMANENT TURF RESTORATION SHALL BE SEED OR SOD (PER HOMEBUILDER). AFTER HOME <br />CONSTRUCTION, <br />THE FOLLOWING SHALL BE INSTALLED WITHIN 24 HOURS OF CONNECTION TO SURFACE WATER: <br />1) ENERGY DISSIPATION UNPRAP) AT ALL OUTLET APRONS <br />2) STABILIZATION OF THE NORMAL WETTED PERIMETER OF ANY TEMPORARY OR PERMANENT <br />DRAINAGE SWALES WITHIN 200 OF EDGE OF SITE OR CONNECTION TO SURFACE WATER <br />SEDIMENT CONTROL PRACTICES <br />A 50 FOOT NATURAL BUFFER SHALL BE MAINTAINED FROM ALL SURFACE WATERS <br />ENTERING/EXITING THE SITE SHALL OCCUR ONLY AT ROCK CONSTRUCTION ENTRANCES TO LIMIT <br />TRACKING OF SEDIMENT ONTO STREETS <br />SEDIMENT TRACKED ONTO STREETS DURING WORKING HOURS MUST BE RECLAIMED VIA <br />SCRAPING AND SWEEPING AT END OF EACH WORKING DAY, <br />TEMPORARY SOIL STOCKPILES SHALL HAVE SILT FENCE OR OTHER EFFECTIVE SEDIMENT <br />CONTROLS INSTALLED AT THE BASE ON THE DOWNGRADIENT PERIMETER. NO STOCKPILE MAY <br />BE PLACED IN ANY NATURAL BUFFERS OR SURFACE WATER <br />IF DEWATERING IS NECESSARY, DISCHARGE SHALL BE TO A TEMPORARY OR PERMANENT <br />SEDIMENT BASIN IF INFEASIBLE, CONTRACTOR MAY DEWATER TO SURFACE WATERS IF THEY <br />VISUALLY CHECK TO ENSURE ADEQUATE TREATMENT HAS BEEN OBTAINED AND NUISANCE <br />CONDITIONS WILL NOT RESULT, NO EROSION OR SCOUR AT THE DISCHARGE POINT SHALL <br />OCCUR AND WETLAND INUNDATION SHALL BE CHECKED THAT IT DOESN'T CAUSE ADVERSE <br />IMPACT TO THE WETLAND. <br />CONSTRUCTION SEQUENCING' <br />1) PRECONSTRUCTION MEETING <br />2) INSTALL PERIMETER SILT FENCE & ROCK CONSTRUCTION ENTRANCE, <br />3) INSTALL DOWNSTREAM INLET PROTECTION TO OFF -SITE CATCH BASINS <br />4) TOPSOIL STRIP. <br />5) ROUGH GRADE SITE & STABILIZE DISTURBED AREAS ACCORDING TO THE NPDES PERMIT <br />TIMELINE LEAVE INFILTRATION BASIN 3' HIGH, INSTALL PERIMETER SILT FENCE AND 510E <br />SLOPE BLANKET AROUND BA51N TO PROTECT DURING CONSTRUCTION, <br />6) INSTALL UTILITIES, <br />T) COMPLETE ROAD CONSTRUCTION. <br />8) COMPLETE INFILTRATION BASIN CONSTRUCTION & RESTORATION. <br />9) INSTALL PRIVATE UTILITIES - GAS, ELECTRIC, TELEPHONE, ETC <br />10) TOPSOIL RESPREAD, <br />11) STABILIZE DISTURBED AREAS WITHIN PERMIT TIMELINE <br />12) HOME CONSTRUCTION. <br />13) RESTORE SITE WITH PERMANENT RESTORATION AS HOMES ARE BUILT <br />14) REMOVE SEDIMENT CONTROL DEVICES AND SUBMIT NOTICE OF TERMINATION (NOT) TO <br />MPCA ONCE ALL DISTURBED AREAS HAVE 70% VEGETATIVE DENSITY. <br />EROSION & SEDIMENT CONTROL BMP ESTIMATED OUANTITES <br />QUANTITIES LISTED ARE APPROXIMATE. REFER TO CONTRACT DOCUMENTS FOR EXACT <br />QUANTITIES <br />BMP EST QUANTITY <br />SILT FENCE <br />6,800 IF <br />ROCK COAST, ENTRANCE <br />1 EACH <br />MNDOT SEED MIX 25-121, TYPE 1 MULCH, <br />12-5-10 TYPE 3 FERTILIZER <br />8 AC <br />SEED OR SOD (PER HOMEBUILDER) <br />8 AC <br />MNDOT SEED MIX 33-261 <br />1, 700 SY <br />IN -STREET INLET PROTECTION <br />18 EACH <br />GREEN AREA INLET PROTECTION <br />1 EACH <br />BIOROLL INLET PROTECTION <br />1 EACH <br />MNDOT 3885 CAT 3N EROSION CONTROL BLANKET <br />6, 560 SY <br />CL, IV RICRAC <br />5.8 CY <br />SEDIMENT TRAP <br />3 EACH <br />CONSTRUCTION NOTES <br />INSPECTIONS AND MAINTENANCE <br />THE CONTRACTOR MUST HAVE A TRAINED PERSON TO ROUTINELY INSPECT THE CONSTRUCTION SITE <br />ONCE EVERY SEVEN (Z) DAYS DURING ACTIVE CONSTRUCTION AND WITHIN 24 HOURS OF A RAINFALL <br />EVENT GREATER THAN 0.5 INCHES IN A 24-HR PERIOD. INSPECTION LOGS SHALL INCLUDE ANY <br />CORRECTIVE MEASURES TO BE TAKEN. CORRECTIVE MEASURES SHALL BE COMPLETED BY THE END OF <br />THE NEXT BUSINESS DAY AFTER DISCOVERY UNLESS OTHERWISE SPECIFIED DUE TO FIELD CONDITIONS <br />THAT PREVENT ACCESS TO THE AREA. <br />ALL INSPECTIONS MUST BE RECORDED AND RECORDS RETAINED WITH THE SWPPP ON SITE THE <br />SWPPP, ALONG WITH INSPECTIONS AND MAINTENANCE RECORDS, SHALL BE RETAINED FOR THREE <br />YEARS AFTER SUBMITTAL OF THE NOTICE OF TERMINATION (NOT). <br />SILT FENCE MUST BE MAINTAINED WHEN ACCUMULATED SEDIMENT REACHES 112 OF THE DEVICE <br />HEIGHT. INLET PROTECTION DEVICES SHALL BE CLEANED ON A ROUTINE BASIS SUCH THAT THE <br />DEVICES ARE FULLY FUNCTIONAL FOR THE NEXT RAINSTORM EVENT REMOVAL AND DISPOSAL OF THE <br />SEDIMENT SHALL BE INCIDENTAL TO THE CONTRACT, <br />ROCK CONSTRUCTION ENTRANCE(O SHALL BE CLEANED AND REFRESHED AS NECESSARY TO <br />CONFORM TO DETAIL, <br />STREET SWEEPING SHALL BE USED IF VEHICLE TRACKING BMP S ARE NOT ADEQUATE TO PREVENT <br />SEDIMENT TRACKING ONTO STREETS <br />POLLUTION PREVENTION' <br />ALL SOLID WASTE GENERATED BY/COLLECTED FROM THE CONSTRUCTION SITE MUST BE DEPOSITED IN <br />A DUMPSTER <br />BUILDING PRODUCTS AND LANDSCAPE MATERIALS SHALL BE PLACED UNDER COVER LIE PLASTIC <br />SHEETING OR TEMPORARY ROOFS). THIS ALSO APPLIES TO PESTICIDES, FERTILIZER AND TREATMENT <br />CHEMICALS <br />NO CONSTRUCTION MATERIAL SHALL BE BURIED OR BURNED ONSTE, <br />ALL HAZARDOUS MATERIALS (OIL, GASOLINE, FUEL, HYDRAULIC FLUIDS, PAINT, ETC) MUST BE <br />PROPERLY STORED IN SEALED CONTAINERS TO PREVENT SPILLS, LEAKS OR OTHER DISCHARGE <br />STORAGE AND DISPOSAL OF HAZARDOUS WASTE MUST BE IN COMPLIANCE WITH MINN. R. CH 7045 <br />CONTRACTOR SHALL ENSURE ADEQUATE SUPPLIES ARE AVAILABLE TO CLEAN UP DISCHARGED <br />MATERIAL AND THAT AN APPROPRIATE DISPOSAL METHOD IS AVAILABLE FOR RECOVERED SPILLED <br />MATERIALS CONTRACTOR MUST REPORT AND CLEAN UP SPILLS IMMEDIATELY, <br />ALL VEHICLES LEFT ONSITE SHALL BE MONITORED FOR LEAKS TO REDUCE THE CHANCE OF <br />CONTAMINATION. <br />EXTERNAL WASHING OF TRUCKS OR OTHER CONSTRUCTION VEHICLES. ENGINE DEGREASING, NOR <br />CONCRETE WASHOUTS ARE ALLOWED ON SITE TRUCKS ARE TO USE SELF-CONTAINED WASHOUT <br />SYSTEM, <br />PORTABLE TOILETS SHALL BE SECURED FROM BEING TIPPED OR KNOCKED OVER. <br />THE CONTRACTOR SHALL MONITOR AND PROVIDE DUST CONTROL CORRECTION WHEN NEEDED. THIS <br />WORK IS CONSIDERED INCIDENTAL TO THE CONTRACT <br />ALL SPILLS SHALL BE CLEANED IMMEDIATELY UPON DISCOVERY SPILLS LARGE ENOUGH TO REACH <br />THE STORM CONVEYANCE SYSTEM SHALL BE REPORTED TO THE MPCA STATE DUTY OFFICER AT <br />1-800-422-0798. <br />FINAL STABILIZATION' <br />THE CONTRACTOR MUST ENSURE FINAL STABILIZATION OF THE SITE PRIOR TO SUBMITTING NOT <br />SUFFICIENT TOPSOIL (6) SHALL BE PLACED ON DISTURBED AREAS FOR RE -VEGETATION, TOPSOIL <br />SHALL BE PLACED IN A MANNER TO MINIMIZE COMPACTION (LOW GROUND PRESSURE DOZERS, <br />TRACKED EQUIPMENT, ETC). <br />VEGETATIVE COVER MUST CONSIST OF A UNIFORM PERENNIAL VEGETATION WITH A DENSITY OF 709 <br />OF ITS EXPECTED FINAL GROWTH. <br />PERMANENT STORMWATER TREATMENT SYSTEMS MUST BE CLEANED OF ANY ACCUMULATED SEDIMENT <br />PRIOR TO SUBMITTNG THE NOT. <br />ALL TEMPORARY EROSION CONTROL MEASURES AND BMP S MUST BE REMOVED AS PART OF THE <br />FINAL SITE STABILIZATION, <br />TRAINING REQUIREMENTS: <br />CONTRACTOR MUST BE TRAINED FOR BOTH CONSTRUCTION INSTALLER AND SITE MANAGEMENT PER <br />REQUIREMENTS OF THE PERMIT, PART II1E DOCUMENTATION SHALL BE ADDED TO THE SWPPP <br />DOCUMENTS LOCATED ONSITE <br />STORMWATER POLLUTION "'"° <br />PRESTIGIOUS WOODLAND HILLS FIFTH ADDITION R 19-0318 <br />�aen� TTO BENZINGER PROPERTIES PREVENTION PLAN NARRATIVE <br />eso m ee..tals,9es`ner :ocs>sez.�ezz ELK RIVER, MN SHEET NO. 9 OF 13 SHEETS ° rF. 2-24-20 <br />