Laserfiche WebLink
SCHEDULE 3-DISTRIBUTED ENERGY RESOURCES INTERCONNECTION PROCESS <br /> Unless the Interconnection Customer provides instruction for how to respond to a <br /> failure of any of the supplemental review screens in the written acceptance of <br /> supplemental review, the Area EPS Operator shall notify the Interconnection Customer <br /> within two (2) Business Days if a supplemental review screen is failed or if the Area EPS <br /> Operator is unable to perform the supplemental review screen. The Area EPS Operator <br /> shall then obtain the Interconnection Customer's permission to either: <br /> • Continue evaluating the proposed interconnection using the supplemental <br /> review screens in Section 4.4. <br /> • Terminate the supplemental review and continue evaluating the <br /> Interconnection Application in the Study Process track. <br /> • Terminate the supplemental review upon withdrawal of the Interconnection <br /> Application by the Interconnection Customer. <br /> The Interconnection Customer shall respond with its choice within five (5) Business <br /> Days of notification from the Area EPS Operator. <br /> 4.4. Supplemental Review Screens <br /> The three supplemental review screens are the Minimum Load screen, the Voltage and <br /> Power Quality screen and the Safety and Reliability screen. <br /> 4.4.1. Minimum Load Screen <br /> The aggregate DER capacity on the line section is less than 100%of the <br /> minimum load for all line sections bounded by automatic sectionalizing <br /> devices upstream of the proposed DER. If minimum load data is not available, <br /> or cannot be calculated, estimated or determined, the Area EPS Operator <br /> shall include the reason(s)that it is unable to calculate, estimate or determine <br /> minimum load in its supplemental review results notification under Section <br /> 4.3. The line section minimum load data shall include onsite load but not <br /> station service load served by the proposed DER in this screen. <br /> The type of generation used by the proposed DER will be considered when <br /> calculating, estimating, or determining circuit or line section minimum load <br /> relevant for the application of this screen. Solar photovoltaic (PV) generation <br /> systems with no battery storage use daytime minimum load (i.e., 10 a.m. to 4 <br /> p.m. for fixed panel systems and 8 a.m. to 6 p.m. for PV systems utilizing <br /> tracking systems), while all other generation uses absolute minimum load. <br /> 8 <br /> 188 <br />