Laserfiche WebLink
Case #CU 18-13 Tammy Anderson CUP <br /> 1. No concerns or issues with the application as proposed. <br /> Case #18-04 Danielle Scharber—site plan review retaining wall/fence/pool <br /> 1. This site is encroaching in to the 20 foot wetland buffer setback area for the pool <br /> and retaining wall location. The wetland area on the west portion of this property is at the <br /> bottom of a steep hill in the backyard. The pool and retaining wall location and installation <br /> will need to be completed in a way to prevent damage to the wetland including erosion <br /> control measures. The encroachment is limited to the proposed pool location and existing <br /> vegetation beyond that area must remain untouched. All retaining walls must include at least <br /> 12 inches of clear backfill material directly behind the wall. The clear backfill material must <br /> be separated from the adjacent soils with landscape fabric. <br /> Case #P 18-12 <br /> CU 18-15 <br /> EV 18-05 <br /> ZC 18-05 River Walk Apartments / Storage Units <br /> 1. Comments previously submitted for this application. The proposed site does not <br /> meet setbacks from the Mississippi River, does not meet bluff setbacks and potential grading <br /> plans are concerning from an environmental standpoint. There is not wetland delineation on <br /> file for this site. <br /> N:\Departments\Community Development\Planning\Case Files\P\P 18-10 Monroe Estates Preliminary Plat\4-Planning <br /> Commission\at\SPR Memo—Environmental August.docx <br />