My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5.3 ERMUSR 09-11-2018
ElkRiver
>
City Government
>
Boards and Commissions
>
Utilities Commission
>
Packets
>
2014-2024
>
2018
>
09-11-2018
>
5.3 ERMUSR 09-11-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2018 10:45:58 AM
Creation date
9/7/2018 2:58:35 PM
Metadata
Fields
Template:
City Government
type
ERMUSR
date
9/11/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
w x <br /> � sem : <br /> 1 . 0 PROJECT INFORMATION <br /> BSI Project No.: WI 1407 Customer P.0.Number: <br /> Customer: City of Elk River, MN Phone: (763) 635-1361 <br /> Street/City/State/Zip: 13069 Orono Parkway, P.O.Box 430, Elk River,MN 55330-0430 <br /> Customer Contact: Eric Volk <br /> Tank Owner: City of Elk River Phone: <br /> Tank Owner Contact: <br /> Client: Elfering&Associates Client Contact: Kristie Elfering Phone: (763)730-0450 <br /> Owner's Tank Designation: Auburn St.Tower <br /> Tank Description: 500,00 Gallon Spheroid <br /> Tank Location(Street/City/State/Zip):_ <br /> Purpose of Inspection: Tank examination and interior and exterior coating evaluation <br /> Date of Inspection: June 19,2018 <br /> Inspected By: Kelly Mulhern& Brian Kollmer <br /> Type of Inspection: BSI Float-down Inspection <br /> Manufacturer: CBI,Inc Construction Date: 1993 <br /> Serial No.: 931426 Design Code: AWWA D-100 <br /> Capacity: 500,000 Gallons <br /> Type of Construction: Welded <br /> Number and Size of Pilasters/Support Columns: One <br /> Tank Diameter: feet+/- <br /> Height: Overall 138'6" Shell/Balcony N/A <br /> Height to: HWL 130'6" LWL 79' <br /> Type of Access to Tank Interior: Roof Manway <br /> Tank Construction Drawings: <br /> Previous Inspection Records: None <br /> EXISTING COATING INFORMATION <br /> INTERIOR WET INTERIOR DRY EXTERIOR <br /> Date Last Coated 1993 1993 2014 <br /> Full or Spot Repair Seamer Seamer Spot <br /> Coating Contractor Unknown Unknown Tom Steele <br /> Surface Preparation SSPC-SP-10 SSPC-SP-6 SSPC-SP-11 <br /> Paint System Epoxy Epoxy Urethane <br /> Paint Manufacturer Tnemec Tnemec Tnemec <br /> Lab Lead Test Paint Chips No No No <br /> PAGE 3 <br /> 130 <br />
The URL can be used to link to this page
Your browser does not support the video tag.