Laserfiche WebLink
I <br /> RYAN <br /> WILDING <br /> -G2'TTv.L+ <br /> ILDING LASTING RELATIONSHIPS <br /> The proposed Data Center requires the following: <br /> A. Electrical <br /> I <br /> A. Provide rate information to The Data Center for primary service: <br /> 1. Total load of 8,884 Kw/10,452 KVA, 0.85 power factor. Service for this I <br /> load will be required by August 2006 for commissions of the data center. <br /> B. Provide Two 15KV Nominal service to a disconnect location on site. I <br /> Conduit from the property line to the disconnect location will be provided by the <br /> I <br /> owner. <br /> B. Water I The Data Center requires its own meter. A 3" domestic water connection to the <br /> building with a water meter is installed. Please verify the location of the meter <br /> (inside or outside the building, on building or in exterior vault) and if branch from <br /> 4111 <br /> water main is inside or outside of the building or if a separate tap is required. The <br /> Data Center determines size of meter on site-specific water pressure. The Data <br /> Center will be responsible for the meter if located inside the building. t <br /> Total Domestic use average (excluding site irrigation) is 137,000 gallons per day. <br /> This includes a peak flow of 142 GPM (204,480 gallons per day) or average flow <br /> I <br /> of 95 GPM (136,800 gallons per day) to the cooling towers. These are estimated <br /> values. The cooling tower blow down rates will depend on the quality of the <br /> water serving the site. <br /> I <br /> Domestic use for occupants will require a peak flow of 60 GPM (86,400 gallons <br /> per day), and an average flow of 900 gallons per day. <br /> I <br /> Target's fire flow requirements are 1270 GPM peak flow with activation of a dry <br /> I <br /> sprinkler system and a hose to extinguish the fire. <br /> Please verify the location of the meter (inside or outside the building, on building <br /> I <br /> or in exterior vault) and if branch from water main is inside or outside of the <br /> building or if a separate tap is required. The Data Center determines size of meter <br /> on site-specific water pressure. <br /> 41: <br /> I <br />