Laserfiche WebLink
MUNICIPAL - 40 UNIT APARTMENT ELK RIVER <br />ELK RIVER, MN <br />BLD1807-00030 <br />7/11/2018 Page 20 <br /> <br /> <br />This information can be provided to you in alternative formats (Braille, large print or audio). <br />An Equal Opportunity Employer <br /> Side-Hinged Door Ovens. Side-hinged door ovens shall have a work surface complying <br />with Section 804.3 positioned adjacent to the latch side of the oven door. [A117.1 Sect. <br />804.5.5.2] <br /> Bottom-Hinged Door Ovens. Bottom-hinged door ovens shall have a work surface <br />complying with Section 804.3 positioned adjacent to one side of the door. [A117.1 Sect. <br />804.5.5.3] <br /> Controls. The location of controls shall not require reaching across burners. [A117.1 <br />Sect. 804.5.5.4] <br /> <br />Dishwasher. <br /> Dishwasher. A clear floor space positioned adjacent to the dishwasher door, shall be <br />provided. The dishwasher door in the open position shall not obstruct the clear floor <br />space for the dishwasher or an adjacent sink. [A117.1 Sect. 804.5.3] <br /> <br />Refrigerator/Freezer. <br /> Refrigerator/Freezer. Combination refrigerators and freezers shall have at least 50 <br />percent of the freezer compartment shelves, including the bottom of the freezer, 54 inches <br />maximum above the floor when the shelves are installed at the maximum heights possible <br />in the compartment. A clear floor space, positioned for a parallel approach to the <br />refrigerator/freezer, shall be provided. The centerline of the clear floor space shall be <br />offset 24 inches maximum from the centerline of the appliance. [A117.1 Sect. 804.5.6] <br /> <br />6. Lounge. <br /> First Floor, 1/A2.0. <br />Appliances in the Lounge are required to be accessible. See Accessibility Comment #5 above for <br />requirements. Please address. <br /> <br /> <br />Structural Comments: <br /> <br />1. Sprinkler Support. <br />Please confirm that the building structure and sprinkler hangers are capable of supporting the <br />sprinkler piping as required by NFPA 13, 9.2.1.3.1. Please address. <br /> <br />Please note that individual structural elements and hangers are also required to meet the <br />requirements of NFPA 13, 9.2.1.3.1 (see below). Note that the 250 lb point load is considered a <br />temporary construction load and is not additive to the supporting structure (example: hanger – <br />yes, joist – yes, beam supporting joist – no). <br /> <br /> Weights of Water-Filled Pipe from NFPA 13 <br /> <br /> Nominal <br /> <br />lb/ft of Water-Filled Pipe