Laserfiche WebLink
MUNICIPAL - 40 UNIT APARTMENT ELK RIVER <br />ELK RIVER, MN <br />BLD1807-00030 <br />7/11/2018 Page 4 <br /> <br /> <br />This information can be provided to you in alternative formats (Braille, large print or audio). <br />An Equal Opportunity Employer <br /> A. Insulation materials and their R-values (MR Table R402.1.1); <br /> B. Fenestration U-factors (MR Table R402.1.1) and SHGCs; <br /> C. Area-weighted U-factor and SHGC calculations; <br /> D. Mechanical system design criteria; <br /> E. Mechanical and service water heating system and equipment types, sizes, <br /> and efficiencies; <br /> F. Equipment and systems controls; <br /> G. Fan motor horsepower (hp) and controls; <br /> H. Duct sealing, and the location and insulation of ducts and pipes; <br /> I. Lighting fixture schedule with wattage and control narrative; and <br /> J. Air sealing details. <br /> <br />8. Commercial Energy Code, Chapter 1323. <br /> Energy Path and Compliance Documentation. <br />Please note that this building is a mixed occupancy and falls under both the Minnesota <br />Residential Energy Code (Chapter 1322) and the Minnesota Commercial Energy Code (Chapter <br />1323). <br /> <br />The S-1 parking garages (see Submittals Comment #9 below) fall under the requirements of the <br />Minnesota Commercial Energy Code (Chapter 1322). <br /> <br />Please indicate which of the options from the Commercial Energy Code MR 1323; Section <br />C401.2.1 has been chosen to obtain compliance [(2012 IECC or ASHRAE 90.1-2010) only one <br />can be used]. Provide supporting documentation for the Lighting as required for the compliance <br />path indicated. <br /> <br /> Mixed Occupancy. Where a building includes both residential and commercial <br />occupancies, each occupancy shall be separately considered and meet the applicable <br />provisions of IECC – Commercial Provisions or IECC – Residential Provision. [MR <br />1323.0100, Subp. 7] <br /> Application (New Buildings). Commercial buildings shall comply with one of the <br />following: [IECC C401.2] <br /> 1. The requirements of ANSI/ASHRAE/IESNA 90.1-2010. <br /> 2. The requirements of Sections C402, C403, C404 and C405. In addition, <br /> commercial buildings shall comply with either Section C406.2, C406.3 or C406.4. <br /> 3. The requirements of Section C407, C402.4, C403.2, C404, C405.2, C405.3, C405.4, <br /> C405.6 and C405.7. The building energy cost shall be equal to or less than 85 <br /> percent of the standard reference design building. <br /> <br />9. Code Summary, Sheet G0.0. <br />Please address the following items in the Code Summary on Sheet G0.0. <br /> <br />The following are the applicable codes for this project. Please confirm compliance, indicate in