My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 5.12
ElkRiver
>
City Government
>
Boards and Commissions
>
Planning Commission
>
Planning Packets
>
2000-2005
>
2002
>
04-23-2002
>
Item 5.12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2018 3:23:14 PM
Creation date
7/16/2018 3:23:11 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Ms. Michele McPherson <br /> April 17, 2002 <br /> Page Two <br /> • No wetland delineation was submitted with the drawings. However, one of <br /> the proposed drainage ponds appears to partially impact the wetland <br /> boundary. A wetland delineation needs to be submitted and if there is any <br /> impact proposed to the wetlands, the project will need to go through a <br /> Technical Evaluation Panel. <br /> • No drainage calculations were submitted. Detailed drainage calculations will <br /> need to be submitted, reviewed, and approved prior to final approval of this <br /> development. The ponds shown on the plat do not have any emergency <br /> overflow elevations. The detailed storm drainage calculations need to include <br /> emergency overflow elevations for the ponds and low point catch basins. <br /> B. SANITARY SEWER AND WATERMAIN PLAN <br /> • There is existing trunk sanitary sewer and watermain that cross this proposed <br /> plat from the east to the west. There is an easement described through this <br /> property which should line up with the proposed east-west road through the <br /> development. <br /> • There are a number of alignment issues with the layout of the utilities which <br /> we can discuss directly with the Developer's engineer prior to them preparing <br /> detailed construction plans. <br /> • The watermain loop that is shown between the two cul-de-sacs needs to be <br /> • HDPE pipe. <br /> C. PRELIMINARY PLAT <br /> • Limited access needs to be provided on the plat adjacent to CSAH 1. <br /> • Easements need to be shown on the plat to encompass the proposed high <br /> water level of the ponds and any drainage that flows outside of prescribed <br /> drainage and utility easements. <br /> D. GENERAL <br /> • The required City street section is 32 feet face to face. <br /> If you have any questions regarding these comments, please call. <br /> Sincerely, <br /> Howard R. Green Company <br /> 440/42 <br /> Terry J./447 <br /> aurer, P.E. <br /> TJM:tw <br /> Ill <br /> Howard R. Green Company <br /> Ltr 417-02 McPherson.rev CONSULTING ENGINEERS <br />
The URL can be used to link to this page
Your browser does not support the video tag.